Specification
MM68
Digital Multimeter
DC CURRENT
Ranges: 220μA, 2200μA, 22mA, 220mA, 10A *
Resolution: 0.01μA, 0.1μA, 0.001mA, 0.01mA, 0.001A
Accuracy: 220μA to 22mA ranges ± (0.5% of rdg + 10 dgts)
220mA range ± (1.0% of rdg + 10 dgts)
10A range ± (2.0% of rdg + 10 dgts)
* Current on 10 A range applied for 60 seconds max followed by a 10 minute
cooling period
Input protection: 0.5A/500V fast blow ceramic fuse
10A/500V fast blow ceramic fuse
TRUE RMS AC CURRENT
Ranges: 220μA, 2200μA, 22mA, 220mA, 10A *
Resolution: 0.01μA, 0.1μA, 0.001mA, 0.01mA, 0.001 A
Accuracy: 220μA to 220mA (50 Hz to 1 kHz) ± (1.5% of rdg + 5 dgts)
10A range (50 Hz to 1 kHz) ± (2.5% of rdg + 5 dgts)
* Current on 10 A range applied for 60 seconds max followed by a 10 minute
cooling period
AC coupled true rms specified from 5% to 100% of range
Crest factor:
≤
3
Input protection: 0.5A/500V fast blow ceramic fuse
10A/500V fast blow ceramic fuse.
RESISTANCE
Ranges: 220
Ω
,
2.2k
Ω
, 22k
Ω
, 220k
Ω
, 2.2M
Ω
, 22M
Ω
, 220M
Ω
Resolution: 0.01
Ω
, 0.0001k
Ω
, 0.001k
Ω
, 0.01k
Ω
, 0.0001M
Ω
, 0.001M
Ω
, 0.1M
Ω
Accuracy: 220
Ω
to
220k ranges ± (0.5% of rdg + 10 dgts)
2.2M
Ω
range ± (1.0% of rdg + 10 dgts)
22M
Ω
range ± (2.0% of rdg + 10 dgts)
220M
Ω
range ± (5.0% of rdg + 10 dgts)
Summary of Contents for MM68