background image

Martindale Electric will carry out routine calibration (on a chargeable basis)
if the instrument is returned, carriage paid, to the address on the final page
of this document. Alternatively, a chargeable collection and return service is
available.

4.5 Repair & Service
There are no user serviceable parts in this unit. Return to Martindale
Electric Company Ltd if faulty, unless fuse replacement only is necessary.
Our service department will promptly quote to repair any faults that occur
outside the warranty period.

4.6 Storage Conditions
The MM35 should be kept in warm, dry conditions away from direct
sources of heat or sunlight, with the battery removed and in such a manner
as to preserve the working life of the multimeter. It is strongly advised that
the unit is not kept in a tool box where other tools may damage it.

4.7 Warranty
Faults in manufacture and materials are fully guaranteed for 2 years from
date of invoice and will be rectified by us free of charge, provided the unit
has not been tampered with and is returned to us with its housing
unopened. Damage due to dropping, abuse or misuse is not covered by the
guarantee. Nothing in these instructions reduces your statutory rights.

Martindale Electric Company Limited

Metrohm House, Penfold Trading Estate, Watford, WD24 4YY, UK.

Tel: +44(0)1923 441717 Fax: +44 (0)1923 446900

E-mail: sales@martindale-electric.co.uk

Website: www.martindale-electric.co.uk

© Martindale Electric Company Ltd.

Registered in England No. 3387451. Rev 2. July 2005

MM35

DIGITAL MULTIMETER

MARTINDALE

E L E C T R I C

Trusted by professionals

INSTRUCTIONS

Summary of Contents for MM35

Page 1: ...erve the working life of the multimeter It is strongly advised that the unit is not kept in a tool box where other tools may damage it 4 7 Warranty Faults in manufacture and materials are fully guaranteed for 2 years from date of invoice and will be rectified by us free of charge provided the unit has not been tampered with and is returned to us with its housing unopened Damage due to dropping abu...

Page 2: ...t html SYMBOLS Equipment complies with relevant EU Directives AC Alternating Current Ground Direct Current Equipment protected by Double Insulation Class II Caution refer to accompanying documents Caution risk of electric shock 4 MAINTENANCE 4 1 Cleaning Maintenance consists of periodic cleaning and battery replacement The exterior of the instrument can be cleaned with a dry clean cloth to remove ...

Page 3: ...t and black lead to COM socket 4 Connect the test leads to the measurement points and take a reading 3 9 1 Diode test 1 Select the rotary switch position and toggle the button until the symbol appears 2 Remove power from the circuit under test 3 Connect the red test lead to the VΩ socket and black lead to COM socket 4 Touch the probes across the diode and take a reading reverse the probes and agai...

Page 4: ...urement 1 Select one of the three current functions using the rotary switch and use button A to choose either DC or AC The appropriate symbol appears at the left hand side of the display 2 When measuring less than 320mA connect the red test lead to the µA mA socket and the black lead to the COM socket 3 For current above 320mA the red lead should be connected to the 10A socket 1 INTRODUCTION 1 1 D...

Page 5: ... or intense electromagnetic fields in the vicinity of the equipment may disturb the measurement circuit Measurement instruments will also respond to unwanted signals that may be present Users should exercise care and take appropriate precautions to avoid misleading results in the presence of electromagnetic interference 3 OPERATION 3 1 Precautions Warning Before using the instrument read the Safet...

Page 6: ...SISTANCE Ranges 320Ω 3 2kΩ 32kΩ 320kΩ 3 2MΩ 30MΩ Resolution 100mΩ Accuracy below 320Ω 2 rdg 3 digits 320Ω to 320kΩ 1 5 rdg 3 digits above 320kΩ 2 5 rdg 3 digits above 3 2MΩ 5 rdg 5 digits Test current 320Ω range 700µA 3 2kΩ range 130µA 32kΩ range 13µA 320kΩ range 1 3µA 3 2MΩ range 0 13µA Overvoltage protection 500V DC or AC rms DIODE TEST Test current 500µA at 0 6V forward voltage Resolution 1mV A...

Reviews: