2. TECHNICAL SPECIFICATION

Display:  3.5 digit liquid crystal (LCD), maximum reading 3200 with floating
decimal point. Updates at 2.5 times per second.
Polarity:  Automatic, implied for positive values, "-" to show negative
readings.
Overrange:  OL  or -OL is displayed.
Zero:  Automatic.
Low battery indication:  A "      " symbol appears when the voltage drops
below that required for correct operation.
Auto Power Off:  After approx. 10 minutes.
Operating:  0 to 50°C @ < 70% relative humidity (RH).
Storage:  -20 to 60°C, 0 to 80% RH (battery must be removed).
Temperature coefficient:  Add (0.1 x % accuracy) per °C from 0 to 18°C,
and from 28 to 50°C.
Maximum altitude:  2,000m.
Battery:  1 x 9 volt, type PP3, MN1604, NEDA1604, JIS006P, IEC 6F22.
Battery life:  200 hours, typical (Zinc - carbon).
Dimensions:  143 x 68 x 47mm (5.6 x 2.7 x 1.9 inches).
Weight:  206g (7.3oz) with battery fitted.
Included: Set of test leads, 9V battery (fitted) & user manual.

DC VOLTS
Ranges:  
200mV, 2V, 20V, 600V.
Resolution:  100µV
Accuracy: ± 1.2% rdg + 1 digit 
Input impedance:  10M

Ω 

Overload protection:  600V DC or AC rms

500V DC / 350V rms for 15 secs on 200mV range

AC VOLTS (50Hz to 500Hz)
Ranges:  200mV, 2V, 200V, 600V
Resolution: 100µV
Accuracy:  ± (2% rdg + 4 digits)
Input impedance: 10M

Ω

Overload protection:  600V DC or AC rms

500V DC / 350V rms for 15 secs on 200mV range 

3. OPERATION

3.1. Precautions
Warning: Before using the instrument, read the Safety Information
Section, and examine it for damage or contamination (excessive dirt,
grease, etc.). Check the test leads for any evidence of cracked or
frayed insulation. If any abnormal conditions exist, do not use the
meter.

Warning: When using probes, keep your fingers behind the guards.

Warning: Measuring voltages which exceed the limits of the meter
may damage it and expose the operator to a shock hazard. Always
work within the meter voltage limits indicated on it's front panel.

Warning: Never ground yourself when taking electrical
measurements. Do not touch exposed metal pipes, outlets, fixtures
etc. which may be at ground potential. Keep your body insulated by
wearing dry clothing, rubber shoes or stand on a rubber mat, or other
suitable material.

3.2 Voltage measurement
1. Connect the red test lead to the "V

Ω

" socket, and the black lead to the

"COM" socket.
2. Select the correct function & range using the rotary switch, ensuring that
AC, or DC, ranges are chosen as appropriate. If the magnitude of the
signal is uncertain, then begin with the highest setting, and reduce it until a
satisfactory indication is obtained.
3. Connect the other end of both test leads to the unit under test.
4. In the DC function a "-" is displayed for negative values, positive
indication is implied.

5

8

Summary of Contents for MM37

Page 1: ...ssary any faults that occur s away from direct nd in such a manner trongly advised that damage it ed for 2 years from e provided the unit s with its housing s not covered by the tatutory rights D24 4YY UK 6900 y 2005 MM37 DIGITAL MULTIMETER MARTINDALE ELECTRIC Trusted by professionals INSTRUCTIONS ...

Page 2: ... leads and any input signals before replacing the battery Replace only with the same type of battery This meter is powered by NEDA type 1604 or equivalent 9V battery When the meter displays the symbol the battery must be replaced to maintain proper operation To replace the battery remove the three screws from the back of the meter and open the bottom case remove the battery from battery compartmen...

Page 3: ...tinuity Test 3 7 Non Contact Voltage Indicator 3 8 Maximum Reading Mode 3 9 Hold Button 4 Maintenance 4 1 Cleaning 4 2 Battery Replacement 4 3 Fuse Replacement 4 4 Calibration 4 5 Repair Service 4 6 Storage Conditions 4 7 Warranty position uce a brief buzz and S on the top of the 60Hz AC voltage is esence of a voltage ble indication nected and AC DC r this mode lay and the reading further press of...

Page 4: ...de test 1 Select the switch position 2 Connect the red test lead to the VΩ socket and black lead to COM socket 3 Remove power from the circuit under test 4 Touch the probes across the diode and take a reading reverse the probes and again take a reading For a silicon diode a value between 0 5 0 6 should be obtained in the forward direction and 1 should be displayed for the reverse direction A value...

Page 5: ...ery life 200 hours typical Zinc carbon Dimensions 143 x 68 x 47mm 5 6 x 2 7 x 1 9 inches Weight 206g 7 3oz with battery fitted Included Set of test leads 9V battery fitted user manual DC VOLTS Ranges 200mV 2V 20V 600V Resolution 100µV Accuracy 1 2 rdg 1 digit Input impedance 10MΩ Overload protection 600V DC or AC rms 500V DC 350V rms for 15 secs on 200mV range AC VOLTS 50Hz to 500Hz Ranges 200mV 2...

Page 6: ...following European Community Directives 89 336 EEC Electromagnetic Compatibility and 73 23 EEC Low Voltage as amended by 93 68 EEC CE Marking However electrical noise or intense electromagnetic fields in the vicinity of the equipment may disturb the measurement circuit Measurement instruments will also respond to unwanted signals that may be present Users should exercise care and take appropriate ...

Reviews: