21

Dimensions and Range of Motion - Light Head

Service Location - Track Light Power Supply

120°

120°

40°

140°

Transformer Cover

6-32 Phillips Head

Screw

Transformer

Insulator

Transformer

Fuses

Ground

Location

Power

Switch

Summary of Contents for TL 500

Page 1: ...TL 500 Track Light Owner s Manual Marus 11727 Fruehauf Drive Charlotte NC 28273 USA Technical Support 800 304 5332 FAX 888 861 9366...

Page 2: ...We will pay the return freight charges from the factory to the dealer This guarantee does not cover dam age resulting from improper installation misuse or accidents incurred in shipping and handling...

Page 3: ...quirements 10 Installation Instructions 10 Adjusting the Light head s Horizontal Rotation 13 Adjusting the Light head s Vertical Rotation 13 Adjusting the Light head s Third Axis Rotation 14 Focusing...

Page 4: ...escriptions calibration instructions or other information that will assist technical personnel to repair and replace serviceable items Product Identification This dental light can be identified by its...

Page 5: ...10 to 90 Relative Humidity The pre installation must be performed according to the requirements in our Pre installation Instructions As manufacturers of electro medical products we can assume respons...

Page 6: ...FUSE 2 AMP 3 AG 230V Electrical Specifications IEC Medical Device Classification Classification 1 Type B Operation Mode Intermittent Splash Protection IPX4 Volts Cycles Amps Dental light 115 VAC 60 HZ...

Page 7: ...promotes simple thorough cleaning Ergonomic handles that reduce stress on wrists and hands A light head that includes a third axis positional adjustment for precise alignment with the oral cavity Sin...

Page 8: ...6 Suggested Mounting Methods Stub out wiring at this point 1 1 4 access hole in mounting pallet 64 35 1 2 33 5 8 Chair Centerline 42 min Recommended Ceiling joists 6 3 3 8 0 min 12 0 max...

Page 9: ...eiling BE SURE TO BRACE STRUCTURE IN BOTH DIRECTIONS MINIMUM SIZE 3 4 PLYWOOD PANEL 77 5 8 x 10 WIDE CEILING JOISTS 16 ON CENTER LAG BOLTS NOT INCLUDED LONG ENOUGH TO GO AT LEAST 3 4 INTO PLYWOOD PANE...

Page 10: ...TRACK PALLET SUSPENDED CEILING PREFORMED BRACKETS PLYWOOD PALLET 77 5 8 10 1 1 2 DIA HOLE 1 1 2 x 3 4 x 1 8 CHANNELS PREFORMED AND BOLTED TO PLYWOOD PALLET Suggestions for Suspended Ceiling continued...

Page 11: ...LOCATED IN TRACK Mounting Parallel and Perpendicular Mounting parallel to ceiling joist on new construction Mounting parallel to ceiling joist on existing construction Mounting perpendicular to ceilin...

Page 12: ...ach end of the track remove the transformer cover and remove the side trim panels The side trim panels are removed by pulling straight outward after the end caps are removed See figure below 2 Use 5 1...

Page 13: ...unter clockwise until it unscrews from the track Slide the trolley onto the track being sure that the wheels that are concave align with the raised side of the track 7 Plug the power cable into the tr...

Page 14: ...ange position according to whether the opera tor is right or left handed THIS SCREW MUST BE USED IN EITHER ONE OF THE TWO LO CATIONS MALFUNCTION AND OR DAMAGE MAY RESULT TO THE LIGHT IF THIS SCREW IS...

Page 15: ...e adjustment on each side to achieve even friction To correct a stiff or loose movement Adjusting the Light head s Horizontal Rotation 1 Remove the plug located at the rear of the pivot housing 2 Inse...

Page 16: ...et of cardboard position ing the bulb shield 27 inches away 2 Turn the light on 3 Using the knob at the back of the light adjust the focus to obtain the sharpest light pattern Pivot nut Back cover Foc...

Page 17: ...e align the pins with the matching holes and press the bulb firmly into place 4 Wipe the glass portion of the bulb clean with denatured alcohol 5 Close the shield by depressing the shield release butt...

Page 18: ...a 5 64 hex wrench 2 Remove the flex arm cover 3 Using a 1 2 wrench adjust the tension bolt until desired tension is set Turn clockwise for more tension turn counter clockwise for less tension 4 Repla...

Page 19: ...r than recommended dilution ratios Only disinfect by wiping no spray disinfection Please be aware that the manufacturer expressly rejects any claims for warranty or damages when using other cleaning a...

Page 20: ...ed Surfaces The painted surfaces of your light can be cleaned by simply wiping with a damp cloth No other protective coating is required to preserve the permanent luster of the painted surface CAUTION...

Page 21: ...19 Dimensions and Range of Motion TL 500 Track Light 58 25 14 75 28 75 10 5 79 54 288...

Page 22: ...0 Dimensions and Range of Motion TL 500 Track Light 16 5 15 42 270 12 39 DIMENSION VARIES DEPENDING UPON CEILING HEIGHT SEE DCI EQUIPMENT CATALOG FOR CHART REGARDING TRACK LIGHT SUSPENSION TUBE LENGTH...

Page 23: ...nsions and Range of Motion Light Head Service Location Track Light Power Supply 120 120 40 140 Transformer Cover 6 32 Phillips Head Screw Transformer Insulator Transformer Fuses Ground Location Power...

Page 24: ...22 Service Location Light Head Bulb Replacement ON OFF Toggle Switch...

Page 25: ...1 BLACK 2 WHITE 3 GREEN 4 RED RED GRN BLK WHT RED GRN BLK WHT 1 2 3 WHT WHT LAMP INTENSITY SWITCH WHT DENT AL LIGHT BLK CONNECTOR PIN LOCA TION 1 2 3 4 RED GRN BLK WHT RED YEL BLK WHT ARM SWITCH 1 BL...

Page 26: ...T 1 BLACK 2 WHITE 3 GREEN 4 RED RED GRN BLK WHT RED GRN BLK WHT 1 2 3 WHT WHT LAMP INTENSITY SWITCH WHT DENTAL LIGHT BLK CONNECTOR PIN LOCATION 1 2 3 4 RED GRN BLK WHT RED YEL GRN BLK WHT ARM SWITCH 1...

Page 27: ...age to the light MEDICAL ELECTRICAL EQUIPMENT ELECTROMAGNETIC COMPATIBILITY TECHNICAL DESCRIPTION ELECTROMAGNETIC COMPATIBILITY testing has been done for this product ACCESSORY USE Using accessory dev...

Page 28: ...No I O lines Mains power quality should be that of typical commercial or hospital environment SURGE IEC 61000 4 5 1 kV differential mode 2 kV common mode 1 kV differential mode 2 kV common mode Mains...

Page 29: ...is product is intended for use in the electromagnetic environment specified below The customer or the user of this product should assure that it is used in such an environment Guidance and manufacture...

Page 30: ...establishments and those directly connected to the public low voltage power supply network that supplies buildings used for domestic purposes RF emissions CISPR 11 RF emissions CISPR 11 Harmonic Emiss...

Page 31: ...er positions If ceiling mount or track mount check the column at the tripod trolley and arm adapter that the roll pin is installed to prevent the column from unscrewing Check all set screws The light...

Page 32: ......

Page 33: ......

Page 34: ......

Page 35: ...____________________________________________ ________________________________________________________________ ________________________________________________________________ _________________________...

Page 36: ...11727 Fruehauf Drive Charlotte NC 28273 USA Technical Support 800 304 5332 FAX 888 861 9366 92353 Rev 5 02 12...