1.  Inspection 

The following items are inside the box: 

 

  User’s Manual 

  UPS 

  Power cord 

 
Remove the Micro UPS from its packaging and inspect it for any damages that may have 
occurred during shipping. If any damage is discovered, re-pack the unit and return it to 
the place of purchase. 
 

2.  Placement of UPS 

Place the Micro UPS in a protected area that is free of excessive dust and provide at least 
7.8 inches (20 cm) clearance on both sides for adequate airflow around the unit. 
 

 
 
 
 
 
 

 

 

  Avoid direct sunlight. 

  Avoid excessive heat. 

  Avoid excessive humidity or liquids. 

  Avoid excessive dust. 

 

3.  Connect UPS to Utility 

Use  the  power  cord  that  came  with  your  UPS  to  connect  the  UPS  directly  to  the  wall 
outlet. 

Do not power the UPS using a surge suppressor or power strip

 

                                       

 

 
Battery Charging:   

                                             

 

The unit is shipped from the factory with its internal battery fully charged, however, some 
charge maybe lost during shipping and the battery should be recharged prior to use. Plug 
the unit into an appropriate power supply and allow the UPS to charge fully by leaving it 
plugged in for at least 8 hours. 
 

4.  Connecting Equipment to UPS 

Connect the equipment to UPS Power Supplied outlets. 
 

 

Battery Power Supplied Outlets & Surge Only Outlets 

 
4 Battery Backup with Surge & 4 Surge only for NEMA outlets 
4 Battery Backup with Surge for IEC outlets 

 
Connect the computer, monitor, and external drive to the "UPS Power Supplied" outlets. 
These outlets provide battery backup, EMI filtering, line conditioning, and surge protection. 
Battery power is automatically provided in case of power failure.     
 

Beware

 of the Power Switch it must be kept in the "ON" position, otherwise, the UPS will 

be disabled and your equipment will not be protected during a power failure. 
 

5.  Connect Modem/Phone/Fax/Network Line   

The Micro UPS 700/900 protects a single 
line RJ-11/45(1 in/1out) phone, modem, fax,   
network device from surges when connected   
through the UPS. Plug in connecting   
internet line into the “IN” socket. 
 
Use one more internet line cable in the 
  “OUT” socket and plug one other end to   
the device input socket as shown in the   
chart below. 

 

6.  Turn On/Off   

To turn on the UPS unit, press the power On/Off Switch once. To turn off the UPS unit, 
press the Power On/Off Switch again.   

 

7.  Cold Start Function   

When the UPS is off and there is no power utility, it's still possible to cold start the UPS 
unit to power the loads.   
 

8.  AC Auto Recovery 

When the UPS is in battery mode and can no longer continue to supply battery power to 
the loads, UPS will shut down. Once AC power is restored, the UPS will automatically 
turn on and supply power to loads and charge battery. 

 

Charging/On AC Indicator 

This green LED flashes when the battery is charging. A lit LED indicates the UPS is 
transferring utility power to the Battery Power Supplied Outlets. 
 

Low Battery/On Battery Indicator 

This orange LED flashes when the battery is low on energy. A lit LED indicates the utility 
power is outside acceptable limits and the battery is supplying power. 
 

Overload/Fault Indicator 

This red LED flashes when there is an overload on the unit. A lit LED indicates a fault with 
the unit. 

UPS

 

Mode

 

Status

 

Green LED

 

Orange LED

 

Red

 

LED

 

Sound

 

 
 
 

 

Line

 

Mode

 

Battery Full. 

Continuously on. 

Off 

Battery charge at 

70%-90%. 

One flash every 

8 seconds. 

Off 

Battery charge at 

50%-70%. 

One flash every 

4 seconds. 

Off 

Battery charge at 

30%-50%. 

One flash every 

2 seconds. 

Off 

Battery charge at 

0%-30%. 

One flash every 

second. 

Off 

UPS  Overload.  UPS 

will  shut  off  at  120% 

of full load. 

On 

Off 

Flash 

Continuous 

beeping. 

 
 

 
 
 

 

Battery
Mode

 

Battery normal. 

Load normal. 

Off 

Two flashes   

every 4 seconds.

Off 

Two (2) beeps 

every 8 seconds. 

UPS overload. UPS 

will shut down at 

120% of full load. 

Off 

Off 

Flash 

Continuous 

beeping. 

 

Over temperature. 

 

Off 

Constant flashes 

every other two 

seconds. 

 

Off 

Sound emitted 

the load 

situation. 

 

UPS short-circuited.

 

Off 

Two flashes   

every 2 seconds,

30 times. 

 

Off 

Two beeps 

every other 2 

seconds, 30 

times. 

Over battery 

voltage. 

Off 

Eight flashes 

every second. 

Off 

Eight beeps 

every second. 

Fault

 

Fault 

Off 

Off 

On 

Continuous 

beeping. 

Off

 

Mode

 

Power off   

(UPS completely off)

Off 

AC normal and 

battery is charging. 

One flash every 2 

seconds. 

Off 

UPS INDICATORS & CONTROLS