USER’S MANUAL 

Micro UPS 
MIC-500A/700A/900A 

 

 

 
UPS contains non-spill able sealed lead-acid batteries. It is important these batteries are 
properly  disposed  of.  Please  see  the  label  on  the  battery  for  recycling  information  for 
proper battery disposal. If no information is available, please contact your local authorized 
distributor or Maruson Customer Service at Custsrv@MarusonUSA.com. 

 

 

 
SAVE THESE INSTRUCTIONS - This manual contains important safety, installation, 
and operating instructions for the Micro UPS 500/700/900 that should be followed 
during installation and maintenance of the UPS and batteries. 

  This UPS utilizes voltage that may be hazardous. Do not attempt to disassemble the 

unit.    The  unit  contains  no  user  replaceable  parts.  Only  factory  service  personnel 
may perform repairs. 

  This  pluggable  type  an  equipment  with  battery  already  installed  by  the  supplier 

operator-installable and may be operated by laymen.   

  The mains socket outlet that supplies the UPS shall be installed near the UPS and 

shall be easily accessible.   

  During the installation  of the equipment, it should be assumed that the sum of the 

leakage currents of the UPS and the connected loads do not exceed 3.5mA.   

  Unplug the UPS prior to cleaning and do not use liquid or spray detergent. 

  Connection  to  any  other  type  of  receptacle  other  than  a  two-pole,  three-wire 

grounded  receptacle  may  result  in  shock  hazard  as  well  as  violate  local  electrical 
codes. 

  In the event of an emergency, press the "OFF" button and disconnect the power cord 

from the AC power supply to properly disable the UPS. 

  Do  not  allow  any  liquids  or  any  foreign  object  to  enter  the  UPS.  Do  not  place 

beverages or any other liquid-containing vessels on or near the unit.   

  This  unit  is  intended  for  installation  in  a  controlled  environment  (temperature 

controlled, indoor area free of conductive contaminants). Avoid installing the UPS in 
locations where there is standing or running water or excessive humidity. 

  Do not plug the UPS input into its own output. 

  Do not attach a power strip or surge suppressor to the UPS. 

  Do not attach non-computer-related items, such as medical equipment, life-support 

equipment, microwave ovens, or vacuum cleaners to UPS. 

  To reduce the risk of overheating the UPS, do not cover the UPS' cooling vents and 

avoid  exposing  the  unit  to  direct  sunlight  or  installing  the  unit  near  heat  emitting 
appliances such as space heater or furnaces. 

  Do not open or mutilate the battery or batteries. Released electrolytes harmful to the 

skin and eyes and may be toxic. 

  Servicing  of  batteries  should  be  performed  or  supervised  by  personnel 

knowledgeable  of  batteries  and  the  required  precautions.  Keep  unauthorized 
personnel away from batteries.   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
1.    AC Input: Connect to input power cord       
2.    AC Fuse/ Circuit Breaker 
3.

   

Backup with surge outlets                               

4.    Surge protection outlets 
5.    RJ-11/45 Combo port           
6.    USB communication port   
        (AS models only) 

 

 

 
 
If any abnormal situations occur that are not listed above, please call for service immediately. When 
calling for service, please have the following information read: 
 
1) Model number and serial number; 
 
2) Date the problem occurred and date of purchase;   
 
3) Full description of the problem, including load, LED, and alarm statuses, installation conditions, 
working environments, etc. 
 
 
 

 

Problem

 

Possible Cause

 

Solution

 

 

 

LED display 

does not turn 

on. 

The UPS is not turned 

on. 

Press and hold the Power button for at 

least 2 seconds. 

Low battery or battery 

voltage less than 10V. 

Charge the battery at least 8 hours. 

 

PCB failure. 

PCB needs to be replaced. Call for 

servicing information. 

 

 

 

UPS is always in 

Battery Mode. 

 

Power cord is loose. 

Reconnect the power cord properly. 

 

Circuit breaker tripped. 

Reset the Circuit Breaker by pushing it 

back in. 

 

PCB failure. 

PCB needs to be replaced. Call for 

servicing information. 

 

 

When power 

fails, back-up 

time is shorter 

than normal. 

The UPS is overload. 

Remove some critical load. 

Battery not fully charged. 

Charge the UPS at least 8 hours. 

Battery defect. It might be 

due to high temperature 

operation environment, or 

improper operation to 

 

Replace the battery with the same 

type of battery. Call for servicing 

information. 

UPS beeps 

continuous

 

UPS is overloaded. 

Remove some loads. 

 

 

 

MODEL 

 

MIC-500A 

MIC-700A 

MIC-900A 

CAPACITY 

VA/W 

500 VA / 250 W 

700 VA / 360 W 

900 VA / 480 W 

INPUT 

Voltage 

110/115/120VAC or 220/230/240VAC 

Voltage Range 

80-145VAC or 154-280VAC 

Frequency 

50/60Hz (Auto Sensing) 

OUTPUT 

Frequency 
Regulation   

50Hz or 60Hz +/-1Hz @ Batt. Mode 

Waveform 

Simulated sine wave 

BATTERY 

Battery Type 

12 V/ 4.5 AH x 1pc 

12 V/ 7 AH x 1pc 

12 V/ 9 AH x 1pc 

Back up Time 

Up to 18 minutes 

Up to 30 minutes 

Up to 40 minutes 

Recharge Time 

< 5 hours to 90% capacity 

TRANSFER TIME 

2-6ms (Typical) 

PROTECTION 

AC Surge 
Protection 

175 Joules 

Phone/Fax/ 
Network Surge 
Protection 

N/A 

RJ-11/45 (1 In 1 Out) 

AC Input 

Circuit breaker 

Full Protection 

Discharge, Overcharge, and Overload Protection 

MANAGEMENT 

 
USB Port 

N/A 

Supports Windows 

2000/2003/XP/Vista/2008/7/8/10, Linux, 

Unix, and MAC. 

PHYSICAL 

Dimension 

  12.4 x 3.9 x 5.6 in (D x W x H) 

Net Weight 

7.7 lbs 

10.4 lbs 

12.6 lbs 

ENVIRONMENT 

Operating 
Environment 

0-40°C, 0-90 % Relative Humidity (non-condensing) 

Noise Level 

Less than 40dB 

 
*Optional 140-295Vac wide input voltage range model for 220/230/240Vac models. 
**Product specification may change without notice. Battery backup time is based on basic PC and   
    varies with equipment, configuration, battery age, temperature, etc.   
 

Product Warranty and Service Information:

 

Warranty obligations its products to be free from defects in material and workmanship during the warranty period. 
This warranty does not apply to any damage, deterioration, or malfunction resulting from accident, misuse, 
neglect, fire, water, lightning, or an adverse operating environment. 
For U.S. customers, please register your product at www.MarusonUSA.com. For international customers, please 
contact your local authorized distributor or e-mail CustSrv@MarusonUSA.com for assistance. 
 

 

Maruson Technology Corporation 
1351 Titan Way, Brea, CA 92821, U.S.A. 
Toll Free: 1-888-MARUSON 
TEL: +1-714-870-6888 
FAX: +1-714-870-4888 
E-mail: Info@MarusonUSA.com 
Web Site: www.MarusonUSA.com 

 

701‐0071200      UPS‐Mar‐MIC700‐900‐01 

BATTERY RECYCLING INFORMATION

Specification 

Safety Caution

 

Panel Information 

Troubleshooting

 

Reviews: