background image

Front Panel—
1. LCD Back-Light 
2. Power “ON/OFF” Switch 

Back Panel—

1.

USB Port 

2. Modem/Phone Line Surge Protection 
3.

Battery Backup Outlets

4.

Surge protected outlets

5.

AC input

6.
*

Circuit breakerz
        IEC

×

3 for 220/230/240V

N

I

T

U

O

2

2

3

4

5

6

1

1

Inspection

Remove the UPS from its packaging and inspect it 

for damage that may have occurred during shipping. 

If any damage is discovered, repack the unit and 

return it to the place of purchase.

Placement 

Charging

Install the UPS unit in any protected environment 

that provides adequate airflow around the unit, and 

is free from excessive dust, corrosive fumes and 

conductive contaminants. Do not operate your UPS 

in an environment where the ambient temperature 

or humidity is high. On the other hand, place the 

UPS unit away from monitor at least 20cm to avoid 

interference. 

This unit is shipped from the factory with its internal 

battery fully charged. however, some energy may be 

lost during shipping so the battery should be 

recharged before using it. Plug the unit into an 

appropriate power supply and allow the UPS to 

charge fully by leaving it plugged in for 8 hours. 

Connect one computer-related device into each of 

the power receptacles supplied on the back of the 

UPS (maximum of three devices).

To turn on the UPS unit, press the power switch lightly.  

To turn off the UPS unit, press the power switch again 

(When Swith ON

The LED lighting.).

The LED will always turns on when UPS works, 

including in off charging mode and fault mode.
When LCD start to work, it will display all information 

for 3s

Plug incoming internet line into the “In” socket at the 

back of the UPS. Use one more Internet line cable 

and plug one end of the Internet line cable to the 

“Out” socket at the back of the UPS. Plug the other 

end to the modem input socket as shown.

Computer Connection 

Modem/Phoneline Connection 

Turn On/Off 

LCD Display Specification 

1).When in normal mode, it will display as below.   

2).When in AVR mode, it will display as below. And the 

mark 

will flicker every 1second. 

3).When  in  battery  mode, it  will display as  below. 

And the  mark 

will flicker every 1second. 

Note: If I/P-V<40V

input voltage will display “000” 

4).When in off charging mode, it will display as below. 

Note: the output voltage always is displayed as “000” 

in off charging  mode.

5).When in fault mode, it will display as below. “FAULT” 

character and  the reason of fault only.   

Note: the fault code will be showed in fault mode. 

6).Load level definition: 

Load LEVEL 

Load bar Indication 

0%~25%

25%~50%

50%~75%

75%~100%

7).Battery capacity definition: 

Battery voltage

≤11

V

11

V

Battery voltage

≤11.

5V

11.

5V

Battery voltage

≤1

2

.5

V

Battery voltage

≥12.

5V

8).When over load, the mark 

  will flicker every 

 1second. 

 1second. 

9).When battery low, the mark 

  will flicker every 

5

4

6

7

3

2

1

UPS System Description

LONG

202-719-4978