background image

-- WinPower -- 

WinPower is a brand new UPS monitoring software, which provides 
user-friendly interface to monitor and control your UPS. This unique 
software provides safely auto shutdown for multi-computer systems while 
power failure. With this software, users can monitor and control any UPS 
on the same LAN no matter how far from the UPS 

Installation procedure: 
1.

Go to the website: 

http://www.ups-software-download.com/winpower.htm

2.

Choose  the  operation  system  you  need  and  follow  the  instruction 

described on the website to download the software. 

3.  When downloading all required files from the internet, enter the serial 

No: 511C1-01220-0100-478DF2A to install the software. 

When your computer restarts, the WinPower software will appear as a 

green plug icon located in the system tray, near the clock. 

Use the table below to solve minor UPS installation or operation 
problems.  If  any  abnormal  situations  occur  that  are  not  listed 
above,please call service people immediately. 

Symptom 

Possible Cause 

Remedy 

1. Missing battery. 

1. Charge battery up to 

8

hours.

2. Battery defect. 

2. Replace with the same type 

of battery. 

No LED display on 

the front panel. 

3.When the Input cord 

isn’t electvified and 

Power switch is not 

pressed. 

3. Press the power switch 

again or elecerity the Input 

cord 

Alarm buzzer 

beeps continuously 

when AC supply is 

normal.

Overload of the UPS. 

Verify that the load matches 

the UPS capability specified in 

the specs. 

1. Overload of the UPS.  1. Remove some noncritical 

load.

2. Battery voltage is too 

low. 

2. Charge battery 

8

 hours or 

more. 

When power 

failure, back-up 

time is shorten. 

3. Battery defect due to 

high temperature 

operation environment, 

or improper operation 

to battery. 

3. Replace with the same type 

of battery. 

1. Software is not 

installed well. 

1. Check the setting of the 

software . 

Communication 

lost between UPS 

and computer. 

2. Cable is not properly 

connected. 

2. Make sure both ends of the

    USB cable is connected

    and recheck settings.

1. Circuit breaker is 

broken. 

1. Reset the circuit breaker.. 

Mains normal but 

LCD display 

Battery mode. 

2. Power cord is loose.  2. Reconnect the power cord 

properly. 

MODEL

PRO-400A LCD PRO-600A LCD

PRO-800A LCD

CAPACITY   

VA/W 

400/240 

600/360 

800/480 

Voltage Range 

89-145VAC/162~290VAC 

INPUT 

Frequency 

50Hz/60Hz (Auto-Sensing) 

Voltage 

110/120/220/230/240VAC 

Voltage Regulation 

+/- 10%(Battery Mode) 

 

z

H

0

6

 

/

 

z

H

0

5

 

y

c

n

e

u

q

e

r

F
Frequency 

Regulation   

+/-1 Hz(Battery Mode) 

OUTPUT 

Output Waveform 

Modified Sine-wave 

Battery Type 

12V/4.5Ah 

12/7Ah 

12V/9Ah 

Back up Time 

Up to 12 mins 

Up to 22 mins

Up to 30 mins

BATTERY 

Recharge Time 

8 Hours to 90% after complete discharge 

TRANSFER TIME 

 

x

a

m

 

s

m

 

0

1

 ,

l

a

c

i

p

y

t

 

s

m

6

-

2

 l

a

c

i

p

y

T

The LCD will always turn on when UPS work, 

INDICATOR 

LCD Display Models

Including in off charging mode and fault mode 

Backup Mode 

Sounding every 10 seconds 

 

d

n

o

c

e

s

 

1

 

y

r

e

v

e

 

g

n

i

d

n

u

o

S

 

w

o

L

 

y

r

e

t

t

a

B

 

s

d

n

o

c

e

s

 

5

.

0

 

y

r

e

v

e

 

g

n

i

d

n

u

o

S

 

d

a

o

lr

e

v

O
Battery replace   

Sounding every 2 seconds 

AUDIBLE ALARM 

 

g

n

i

d

n

u

o

s

 

s

u

o

u

n

it

n

o

C

 

tl

u

a

F
Buck/boost with   

>70% SPS load 

Sounding every 0.5sec. after 25min. 

And fault after 30 mins 

PROTECTION 

Full Protection 

Discharge,Overcharge short circuit   

and Overload Protection 

PHYSICAL 

Dimension (DxWxH) 

330 x 100 x 140mm/12.9 x 3.9 x5.5 inch 

WEIGHT 

Net Weight 

4.4Kg/9.7lb

5.4Kg/11.9lb

6.1Kg/13.4lb 

Operating   

Environment 

0- 40°C, 0-90 % Relative Humidity (non-condensing)

ENVIRONMENT 

 

B

d

0

4

 

n

a

h

t

 

s

s

e

L

 l

e

v

e

L

 

e

s

i

o

N

INTERFACE 

For Windows Family, Mac, Linux Family,

             and Unix Based Famillies 

USB

(Software included)

Software Installation

This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user serviceable parts. 

Only factory service personnel may perform repairs.

Internal battery voltage is 12Vdc. Sealed, lead-acid, 6 cells battery.

Connection to any other type of receptacle other than a two-pole, three-wire grounding receptacle may result in s shock hazard as well 

as violate local electrical codes.

In the event of an emergency, turn the power switch to the “off” position and disconnect the power cord form the AC power supply to 

properly disable the UPS

Do not allow any liquids or any foreign object to enter the UPS. Do not place beverages or any other liquid-containing vessels on or near 

the unit.

Do not plug the UPS input into its own output.

Do not attach a power strip or surge suppressor to the UPS.

To reduce the risk of overheating the UPS, do not cover the UPS’ cooling vents and avoid exposing the unit to direct sunlight or installing the 

unit near heat emitting appliances such as space heaters or furnaces.

Do not attach non-computer-related items, such as medical equipment, life-support equipment, microwave ovens, or vacuum cleaners to UPS.

Unplug the UPS prior to cleaning and do not use liquid or spray detergent.

Do not dispose of battery or batteries in a fire.  The battery may explode.

Do not open or mutilate the battery or batteries.  Released electrolyte is harmful to the skin and eyes.  It may be toxic.

Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions.  

Keep unauthorized personnel away from batteries.

When replacing batteries, replace with the same number of the sealed lead-acid batteries.

This pluggable type A equipment with battery already installed by the supplier is operator installable and may be operated by laymen.

During the installation of this equipment it should be assured that the sum of the leakage currents of the UPS and the connected 

loads does not exceed 3.5mA.

The mains socket outlet that supplies the UPS shall be installed near the UPS and shall be easily accessible.

A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed when working 

on batteries :

1) Remove watches, rings, or other metal objects from the hand.

2) Use tools with insulated handles.

3) Wear rubber gloves and boots.

4) Do not lay tools or metal parts on the top of batteries.

5) Disconnect charging source prior to connecting or disconnecting batteries terminal.

This unit intended for installation in a controlled environment (temperature controlled, indoor area free of conductive contaminants). 

Avoid installing the UPS in locations where there is standing or running water, or excessive humidity.

All trade names are registered trademarks of respective manufacturers listed.

Specifications may change without notification.