CAUTION - 

Batteries are considered HAZARDOUS WASTE and must be disposed of properly.    Most 

retailers that sell lead-acid batteries collect used batteries for recycling, or you can contact your local 

recycling center for proper disposal information.

 

 

TECHNICAL SPECIFICATIONS 

 

Model 

 

PRO- 

550LCD 

PRO- 

800LCD 

PRO- 

1000LCD 

PRO- 

1500LCD 

PRO- 

2000LCD 

Capacity    (VA/W) 

550/300 

800/450 

1000/600 

1500/900 

2000/1200 

Input 

 

 

 

 

Voltage Range 

82~148Vac 

Frequency 

60/50Hz(Auto Sensing) 

Output 

 

 

 

 

Voltage (Batt. Mode) 

Simulated Sine Wave at 110-120Vac 

Frequency(Batt. mode 

60/50 Hz +/-1Hz 

Overload Protection 

Breaker/Internal Current Limiting 

Physical 

 

 

 

 

Outlets-total 

Bat.&Surge Protected 

Surge Only Protected 

Dimensions 
(W X H X D) 

3.78 X 5.43 X 11.25 in/ 

96 X 138 X 286mm 

5.82 X 7.0 X 11.73in/ 

148 X 178 X 298mm 

Weight    lbs/kg 

9.59/4.35 

11.19/5.08 

19.09/8.66 

23.48/10.65 

25.04/11.36 

Battery 

 

 

 

 

Type & Quantity 

12V/7AH*1 

12V/7.2AH* 1  12V/7AH*2 

12V/7.2AH*2 

12V/9AH*2 

Recharge Time 

4 Hours to 90% capacity 

Warning Diagnostics 

Indicators 

Power On, UPS Status Display, Capacity Display, Digital Value Display 

Audible Alarms 

On Battery, Low Battery, Overload 

Environmental 

 

 

 

 

Operating Temp. 

0

°

C to 40

°

C   

Operating Humidity 

0 to 90% 

Communication 

 

 

 

 

Power Master 
software 

Windows 10, Windows 8, Windows 7, Windows Server 2012 R2,     

Windows Server 2008 R2, Linux, Mac

 

Management 

 

 

 

 

Auto-Charger 

Yes 

Auto-Restart 

Yes 

USB 

Yes 

RJ-11/45 Protected 

Yes 

 

DEFINITIONS FOR ILLUMINATED LCD INDICATORS 

 

LCD Indicator 

 

 

 

 

 

 

 

Line mode 

UPS  is  running  from  an 

input line power source. 

 

Battery Mode 

UPS is running on 

battery mode due to 

power failure or severe 

input voltage fluctuation. 

 

 

Fault 

UPS detected a fault   

 

Mute/Silent

 

Press the display key   

2 times

 

to disable and 

enable the alarm 

beeping sound. 

 

mute function only for 

Sounding every 30 

seconds on battery 

mode. 

 

 

Bat mode: battery capacity 

Line mode:   

1. Battery charging: cycle 

lighting 

2. Battery full charged: 

lighting 

3. Line mode without 

charger: battery capacity 

 

Load Capacity 

Reports load-level of the 

UPS supported outlets. 

 

Line Mode & BATT. Mode 
 

 

 

 

Initial 

AC INPUT(Voltage) 

 

OUTPUT(Voltage) 

 

 

TROUBLE SHOOTING

 

 

Problem 

Possible Cause 

Solution 

The UPS does 

not perform 

expected 

runtime. 

Batteries are not fully charged. 

Recharge the battery by leaving the UPS 

plugged in. 

Battery is slightly worn out. 

Contact Technical Support. 

The UPS will not 

turn on. 

 

The on/off switch is designed 

to prevent damage by rapidly 

turning it off and on. 

Turn the UPS off. Wait 10 seconds and then 

turn the UPS on. 

The unit is not connected to an 

AC outlet. 

The unit must be connected to a 120Vac 

50/60Hz outlet.     

The battery is worn out. 

Contact Technical Support. 

Mechanical problem. 

Contact Technical Support.   

Outlets do not 

provide power to 

equipment 

Circuit breaker is tripped due 

to overload 

Turn the UPS off and unplug at least one 

nonessential equipment. Unplug the power 

cord of the UPS then press the circuit 

breaker knob to depress the breaker.     

Batteries are discharged 

Allow the unit to recharge for at least 4 

hours. 

Unit has been damaged by a 

surge or spike. 

Contact Technical Support.   

Power Guide is 

inactive 

The serial/USB cable is not 

connected. 

Connect the serial/USB cable to the UPS 

unit and an open serial port on the back of 

the computer. You must use the cable that 

came with the unit. 

The unit is not providing 

battery power. 

Shutdown your computer and turn the UPS 

off. Wait 10 seconds and turn the UPS back 

on. This should reset the unit. 

 

FCC COMPLIANCE STATEMENT 

 

FCC Compliance Statement 

This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) 

this device may not cause harmful interference, and (2) this device must accept any interference received, 

including interference that may cause undesired operation. 

Note

: This equipment has been tested and found to comply with part 15 of the FCC Rules. These limits are 

designed to provide reasonable protection against harmful interference in a residential installation. This 

equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in 

accordance with the instructions, may cause harmful interference to radio communications. However, 

there is no guarantee that interference will not occur in a particular installation. If this equipment does 

cause harmful interference to radio or television reception, which can be determined by turning the 

equipment off and on, the user is encouraged to try to correct the interference by one or more of the 

following measures: 

- Reorient or relocate the receiving antenna. 

- Increase the separation between the equipment and receiver. 

- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. 

- Consult the dealer or an experienced radio/TV technician for help. 

Important

: Changes or modifications not expressly approved by the party responsible for compliance 

could void the user's authority to operate the equipment. 

Canadian Compliance 

CAN ICES-3 (B)/NMB-3(B) 

 

SOFTWARE DOWNLOAD (OPTIONAL) 

 

Download the Power Master software to fully utilize this UPS model. The Power Master software provides 

a user-friendly interface to configure your UPS settings and provides essential power information at a 

glance.   

Installation procedure: 

1. 

Download the Power Master software from 

http://www.marusonusa.com. Select “Support” 

and locate the “Software” option.   

2. 

Double-click the file and follow the installation 

steps. 

3. 

When your computer restarts, the Power Master 

software will appear as a blue icon located in the 

system tray. 

 

 

 

 

 

 

 

Copyright © 2017 All Rights Reserved. Maruson® is a registered trademark of Maruson Technology (U.S. 

Trademark Register No. 3,150,957). All other trademarks listed are the property of their respective owners.                                   

  VER-PRO1709 

K01-C000413-00

 