Page 58
mPower 300 Series (Rev G)
3000 W Models
80 V : 100 A
300-11-0080-100
200 V : 50 A
300-11-0200-050
360 V : 30 A
300-11-0360-030
500 V : 20 A
300-11-0500-020
65- V : 12 A
300-11-0750-012
AC Input
Input voltage, frequency
207–264 Vac, 45–66 Hz to acheive maximum power output
180–207 Vac, 45–66 Hz yields derated 2500 W power output
Input connection
1ph (L, N, GND)
Input fuse (internal)
T16 A
Leak current
< 3.5 mA
Power factor
≈ 0.99
Idle mode power consumption
≈ 70 W
DC Output
Max. output voltage U
Nom
80 V
200 V
360 V
500 V
750 V
Max. output current I
Nom
100 A
50 A
30 A
20 A
12 A
Max. output power P
Nom
3000 W with input ≥ 207 Vac
2500 W with input ≤ 207 Vac
Overvoltage protection range
0–88 V
0–220 V
0–396 V
0–550 V
0–825 V
Overcurrent protection range
0–110 A
0–55 A
0–33 A
0–22 A
0–13,2 A
Overpower protection range
0…3300 W
0…3300 W
0…3300 W
0…3300 W
0…3300 W
Temperature coefficient
Voltage / current: 100 ppm/K
Output capacitance (approx.)
8930 μF
1500 μF
705 μF
150 μF
70 μF
Voltage regulation
Adjustment range
0–81.6 V
0–204 V
0–367.2 V
0–510 V
0–765 V
Accuracy
(1
(at 23±5°C / 73±9°F)
< 0.1% U
Nenn
< 0.1% U
Nenn
< 0.1% U
Nenn
< 0.1% U
Nenn
< 0.1% U
Nenn
Line regulation at ±10% ΔU
AC
< 0.02% U
Nenn
< 0.02% U
Nenn
< 0.02% U
Nenn
< 0.02% U
Nenn
< 0.02% U
Nenn
Load regulation at 0–100% load
< 0.05% U
Nenn
< 0.05% U
Nenn
< 0.05% U
Nenn
< 0.05% U
Nenn
< 0.05% U
Nenn
Rise time 10–90% ΔU
Max. 15 ms
Max. 15 ms
Max. 15 ms
Max. 15 ms
Max. 15 ms
Transient time after load step
< 1.7 ms
< 1.4 ms
< 2.2 ms
< 2 ms
< 2 ms
Display: Resolution
See section
3.2.2. Resolution of the displayed values
Display: Accuracy
(3
≤ 0.2% U
Nom
≤ 0.2% U
Nom
≤ 0.2% U
Nom
Ripple
(2
< 76 mV
PP
< 4.2 mV
RMS
< 234 mV
PP
< 40 mV
RMS
< 156 mV
PP
< 26 mV
RMS
< 234 mV
PP
< 50 mV
RMS
< 260 mV
PP
< 40 mV
RMS
Remote sensing compensation
Max. 5% U
Nom
Max. 5% U
Nom
Max. 5% U
Nom
Max. 5% U
Nom
Max. 5% U
Nom
Fall time (at no load) after switching
DC output off
Down from 100% to <60 V: less than 10 s
Current regulation
Adjustment range
0–102 A
0–51 A
0–30.6 A
0–20.4 A
0–12.24 A
Accuracy
(1
(at 23±5°C / 73±9°F)
< 0.2% I
Nenn
< 0.2% I
Nenn
< 0.2% I
Nenn
< 0.2% I
Nenn
< 0.2% I
Nenn
Line regulation at ±10% ΔU
AC
< 0.05% I
Nenn
< 0.05% I
Nenn
< 0.05% I
Nenn
< 0.05% I
Nenn
< 0.05% I
Nenn
Load regulation at 0–100% ΔU
OUT
< 0.15% I
Nenn
< 0.15% I
Nenn
< 0.15% I
Nenn
< 0.15% I
Nenn
< 0.15% I
Nenn
Ripple
(2
< 114 mA
PP
< 29 mA
PP
< 10 mA
PP
< 9.2 mA
PP
< 4.1 mA
PP
Display: Resolution
See section
3.2.2. Resolution of the displayed values
Display: Accuracy
(3
≤ 0.2% I
Nom
≤ 0.2% I
Nom
≤ 0.2% I
Nom
≤ 0.2% I
Nom
≤ 0.2% I
Nom
8.4 MPW 300-11 : 1U, 3,000 Watt, 200–240 Vac