Page 28
mPower 300 Series (Rev G)
5.4.3.1 Menu “General Settings”
Element
P.
Description
Allow remote control
1
Selection “NO” means that the unit cannot be remotely controlled over any of
the digital or analog interfaces. If remote control is not allowed, the status will be
shown as “Local” in the status area on the main display. Also see section
Analog interface range
2
Selects the voltage range for the analog inputs, actual output values and the
reference voltage output of the analog interface on the rear.
0–5 V = 0-5 V correspond to 0–100% set /actual values, reference is 5 V
0–10 V = 0-10 V correspond to 0–100% set /actual values, reference is 10 V
See also section
5.5.4. Remote control via the analog interface
Analog interface Rem-SB
3
Determines with “normal” (default), that the function and levels of input Rem-SB
are as described in
5.5.4.4. Analog interface specification
. With selection “invert-
ed”, the described function is logically inverted. Also see example a) in
.
Analog Rem-SB action
4
Since Firmware 2.03, the input REM-SB of the analog interface can be used to
control the DC output of the unit even without remote control via analog interface
being activated. This setting determines the type of action:
DC OFF = Toggling the pin only switches the DC output off
DC ON/OFF = If the DC output has been switched on before, toggling the pin can
switch the output off and on again
DC output after power ON
5
Determines the condition of the DC output after power-up.
OFF = DC output is always off after switching on the unit.
Restore = DC output condition will be restored to the condition prior to switch off.
DC output after PF alarm
6
Determines how the DC output shall react after a power fail (PF) alarm has oc-
curred:
OFF = DC output will be switched off and remain until user action
AUTO = DC output will switch on again after the PF alarm cause is gone and if it
was switched on before the alarm occurred
Share Bus mode
7
Default setting: Slave
For parallel operation of multiple units, where using the Share bus connection is
recommended. In parallel operation, any unit could be master.
5.4.3.2 Menu “Calibrate Device”
From within this menu, a calibration and readjustment procedure for output voltage and current, separate procedures for
set value and actual value, can be started. For further details refer to
6.3. Calibration (readjustment)
.
Element
Description
Voltage
Starts the semi-automatic calibration procedure for output voltage U
Sense volt.
Starts the semi-automatic calibration procedure for remote sensing input „Sense“
Current
Starts the semi-automatic calibration procedure for output current I
Cal. date
Here you can enter the date of the most recent calibration (year, month, day)
Save & exit
This menu item saves and leaves the setup menu to main display