3765-2 Dual-Handed Swingbolt Lock Instructions
OPENING THE LOCK
➀
Enter valid six (6) digit code.
➁
The lock will indicate a valid code entry with a double signal.
➂
Within four (4) seconds, turn handle to the open position.
④
Pull door open.
●
Invalid Code Entry - Lock will signal three (3) times.
●
Security Considerations - On safes using more than one
lock the swingbolt lock must lock first.
CHANGING YOUR CODE
ALWAYS PERFORM THIS OPERATION WITH
THE DOOR OPEN
➀
Enter “zero” six times.
➁
Enter your existing six (6) digit code one time.
➂
Enter your NEW six (6) digit code two times.
④
If a mistake is made wait thirty (30) seconds and repeat
steps
➀
-
➂
.
➄
Test lock operation several times before closing the door.
●
Valid Code Entry - Double signal after valid six (6) digit
code is entered.
●
Invalid Code Entry - Triple signal and old code is still valid.
ADD USER
ALWAYS PERFORM THIS OPERATION WITH
THE DOOR OPEN
➀
Enter Manager code and HOLD DOWN LAST DIGIT of
CODE until the lock signals with two sets of double beeps.
➁
PRESS 1. Lock signals twice.
➂
Enter user code twice. The lock signals twice after each
valid entry.
④
If a mistake is made wait thirty (30) seconds and repeat
steps
➀
-
➂
.
●
Valid Code Entry - Double signal after valid six (6) digit
code is entered.
●
Invalid Code Entry - Triple signal and old code is still valid.
DISABLE USER
ALWAYS PERFORM THIS OPERATION WITH
THE DOOR OPEN
➀
Enter Manager code and HOLD DOWN LAST DIGIT of
CODE until the lock signals with two sets of double beeps.
➁
PRESS 2. Lock signals once.
➂
User is temporarily disabled.
④
If a mistake is made wait thirty (30) seconds and repeat
steps
➀
-
➂
.
●
Valid Code Entry - Double signal after valid six (6) digit
code is entered.
●
Invalid Code Entry - Triple signal and old code is still valid.
FEATURES
MANAGER CODE
(Factory set to 1-2-3-4-5-6)
●
Add/Remove User
●
Enable/Disable User
USER CODE
●
Open Lock
●
Change Code
WRONG TRY PENALTY
●
Four (4) consecutive invalid codes initiates five
minute delay period.
LOW BATTERY WARNING
●
Repeated audio and visual signal (LED flashing and
repeated beeping) during opening indicates battery low.
AUDIO AND VISUAL SIGNAL
●
Double signal (LED flashes and unit beeps) indicates
entry is valid or accepted.
●
Triple signal indicates invalid or not accepted.
© copyright 2003 12-219V1
LA GARD INC - A MASCO COMPANY
MANAGER PROGRAMMING
Suggested Keypads
3710 Angular Input
3000 Round Entry
3900 LGACCESS
Handle