REINSTATE USER

ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN

Enter Manager code and HOLD DOWN LAST DIGIT of CODE until the lock signals with two sets of double beeps.

PRESS 1. Lock signals once.

User is reinstated.

If a mistake is made wait thirty (30) seconds and repeat steps 

.

Valid Code Entry - Double signal after valid six (6) digit code is entered.

Invalid Code Entry - Triple signal and old code is still valid. 

REMOVE USER

ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN

Enter Manager code and HOLD DOWN LAST DIGIT of CODE until the lock signals with two sets of double beeps.

PRESS 3. Lock signals once.

User is permanently removed.

If a mistake is made wait thirty (30) seconds and repeat steps 

.

Valid Code Entry - Double signal after valid six (6) digit code is entered.

Invalid Code Entry - Triple signal and old code is still valid. 

WRONG TRY PENALTY

Entry of four (4) consecutive invalid codes starts a 5-minute delay period.

- LED flashes red at ten (10) second intervals.

At the end of the delay period, two more consecutive invalid codes will restart an additional 5-minute delay period.

Entry will not respond to a single keystroke during delay period.

BATTERY LOW WARNING

Repeated beeping during an opening indicates that the battery is low and needs immediate replacement.

Uses one (1) 9-Volt Alkaline Battery. LA GARD recommends the use of Duracell™ or Eveready™
Alkaline batteries. LA GARD recommends the replacement of batteries at least once annually.

If battery is depleted and will not allow lock to open, simply follow instructions below. Lock
contains a non-volatile memory, even with batteries removed the lock will retain all programming.

CHANGING YOUR BATTERY

(3710 Angular Input)

Note: Some manufacturers use a small screw to secure the battery compartment cover to the keypad
housing. If your model has this screw, it must be removed first before following the steps listed below.

Remove black plastic battery compartment cover (located at the bottom of the keypad) by gently
pulling downward on it’s handle.

Allow the battery and it’s attached leads to drop down and out of the battery compartment. If it
does not drop, gently pull on the battery until it does.

The connector is easily removed by unsnapping it from the two terminals on the top of the battery.

Never Pull on the Battery Leads

Connect a new 9-Volt Alkaline battery to the battery clip.

Push the battery and the leads completely up into the battery compartment.

Install the battery cover by placing one side of the cover in position and then pressing
the other side into position with your finger.

CHANGING YOUR BATTERY

(3000 Round Entry)

Slide the keypad housing up and carefully pull away from mounting
surface to expose battery compartment.

Remove one (1) 9-Volt Alkaline battery and replace with new one.

The connector is easily removed by unsnapping it from the two terminals
on the top of the battery.

CAUTION! Hold onto battery terminal cap to avoid pulling wires 
out of housing.

Repeat procedure for second battery.

Carefully position the keypad over the mounting screws and slide the
keypad housing down. Ensure that there are no wires or cables trapped
between the input pad and the safe door. Pinched cables can result in
a short circuit.

3000 Round Entry

3710 Angular Input