MARINER
1800-2100-2400-2700-2500T-3000T-3400T
- 18
GB
GB
2.3 T
ECHNICAL
CHARACTERISTICS
TABLE
(1)
Limited - time running power (LTP) ISO 8528-1
It is the maximum power that, under the environment conditions established by the norm ISO 3046/1, the generator group it is able to disburse
for a maximum of 500 hours for year, of which a maximum of 300 hours among the interval of maintenance prescribed by the builder. It
is accepted the operation to this power conditions the duration of the group.
An overload of the 10% is admitted only for regulation.
(2)
Prime power (PRP) ISO 8528-1
It is the available maximum power for a variable power cycle that the generator group is able to disburse for a boundless number of hours
for year among the interval of maintenance prescribed by the builder and under the environment conditions established by the norm ISO
3046/1. The middle power during a period of 24 hours, doesn't have to exceed 80% of the PRP.
An overload of the 10% is admitted only for regulation.
MAX POWER (LTP)
1
20
23
26
kVA
CONTINUOUS POWER (PRP)
2
18
21
24
kVA
POWER FACTOR (Cos
Φ
)
1
1
1
RATED VOLTAGE
230
230
230
V
RATED FREQUENCY
50
50
50
Hz
GRADE OF PROTECTION
IP 23
IP 23
IP 23
MAX TEMP. OF USE
40 - 104
40 - 104
40 - 104
°C - °F
MIN TEMP. OF USE
-5 - 23
-5 - 23
-5 - 23
°C - °F
MAX ALTITUDE OF USE
1000 - 3280
1000 - 3280
1000 - 3280
m - ft
MAX INCLINATION DURING USE
(PERIODICAL 3 min)
30°
30°
30°
MAX TILT OF USE (CONTINUOUS)
25°
25°
25°
SEAWATER PUMP FLOW
25 - 6,6
25 - 6,6
25 - 6,6
L/min - gal/min
L
1295 - 50
1295 - 50
1295 - 50
mm - in.
DIMENSIONS
W
630 - 25
630 - 25
630 - 25
mm - in.
H
810 - 32
810 - 32
810 - 32
mm - in.
MASS
625 - 1388
625 - 1388
625 - 1388
kg - lbs
TYPE
4 STROKE
5 STROKE
6 STROKE
MANUFACTER
YANMAR
YANMAR
YANMAR
MODEL
4 TNV 98
4 TNV 98
4 TNV 98
DISPLACEMENT
3319 - 169,4
3319 - 169,4
3319 - 169,4
cm
3
- in
3
MAX POWER
47 - 34,5
47 - 34,5
47 - 34,5
HP - kW
n° OF CYLINDERS
4
4
4
CYLINDERS / HEAD MATERIAL
ALLUMINIUM
ALLUMINIUM
ALLUMINIUM
RATED SPEED
1500
1500
1500
rpm
SPEED CONTROL
CENTRIFUGAL/MECCANICAL CENTRIFUGAL/MECCANICAL CENTRIFUGAL/MECCANICAL
INDUCTION SYSTEM
NATURAL
NATURAL
NATURAL
FUEL
DIESEL
DIESEL
DIESEL
INJECTION SYSTEM
DIRECT
DIRECT
DIRECT
FUEL FEEDING PUMPS
ELECTRIC
ELECTRIC
ELECTRIC
MAX PREVALENCE FUEL PUMP
700 - 27,5
700 - 27,5
700 - 27,5
mm - in.
FULL LOAD CONSUMPTION
5,7 - 1,5
6,7 - 1,7
7,6 - 2
L/h - gal/h
COOLING
AIR / WATER
AIR / WATER
AIR / WATER
LUBRIFICATION SYSTEM
FORCED
FORCED
FORCED
OIL SUMP CAPACITY
10,5 - 2,7
10,5 - 2,7
10,5 - 2,7
L - gal
COMBUSTION AIR VOLUME
2,24 - 78,4
2,24 - 78,4
2,24 - 78,4
m
3
/min - cfm
ELECTRIC PLANT
12
(negative pole to ground)
13
(negative pole to ground)
14
(negative pole to ground)
V
STARTING
ELECTRIC
ELECTRIC
ELECTRIC
STARTING MOTOR
12 - 0,9
12 - 0,9
12 - 0,9
V - kW
STARTING BATTERY
12 - 70
12 - 70
12 - 70
V - Ah
BATTERY CHARGER
12 - 40
12 - 40
12 - 40
V - A
STOPPING SYSTEM
SOLENOID
SOLENOID
SOLENOID
TYPE
SYNCHRONOUS,
SELF-REGULATED
SYNCHRONOUS,
SELF-REGULATED
SYNCHRONOUS,
SELF-REGULATED
n° OF POLES
4
4
4
MAX CURRENT
87,0
100,0
113,0
A
ISOLATION CLASS
H
H
H
VOLTAGE REGULATOR
SELF-EXCITED
SELF-EXCITED
SELF-EXCITED
VOLTAGE STABILITY
±2%
±2%
±2%
FREQUENCY STABILITY
±5%
±5%
±5%
COOLING
AIR
AIR
AIR
MARINER MODEL
GENERAL FEATURES
ALTERNATOR
ENGINE
1800
2100
2400