MARINER
1800-2100-2400-2700-2500T-3000T-3400T
- 32
GB
GB
3
2
1
4
6
7
5
A
5 PROTECTIONS AND WARNING SIGNALS
5.1 E
NGINE
PROTECTION
MODULE
The generators are equipped with a series of protections
which safeguard it against improper use and faults which
may compromise integrity.
When the generator stops because one of the safety
switches has tripped, the indication of the hours of
operation disappears from the control panel display
(
ref.A
) and a code appears to indicate the cause of the
generator stop.
- “RUN” warning light 1
When on (green) it signals proper functioning of the
generator and that no fault has been detected.
- “Oil” warning light 2 - Low oil pressure protection
When on (red) it signals insufficient engine oil pressure
and shutdowns the generator.
Fill up with oil in order to restart the generator.
- “°C” warning light 3 - High alternator temperature
protection
When on (red) switches off the generator when the
alternator operating temperature is too high.
The generator can be restarted after few minutes
when the windings alternator temperature come back
to normal value.
- Warning light 4 - C.B. failure protection
When on (red) it signals a fault on the battery charger
alternator or belt breakage.
- Warning light 5 - High engine temperature
protection
When on (red) switches off the generator when the
engine operating temperature is too high or when the
seawater flush stops.
- Warning light 6 - Glow plug preheating
When on (yellow) it signals the use of glow plug.
- Warning light 7 - General emergency
Not used
The low oil pressure protection does not give an
indication of the oil level. The oil level must daily
be checked in order to prevent damage to the
engine.
The engine correctly works if it doesn't exceed
inclinations max of 30° for up to 3 minutes and 25°
without limits of time, in comparison to both
longitudinal and transversal axles. If the engine
works to greater inclinations, it risks an
insufficient lubrication and/or aspiration of oil
from the filter air.
If one of the above safety switches trip, find and
eliminate the cause and then press the STOP button
to reset the control panel (otherwise the signal
would remain in memory inhibiting engine starting).