Installation Manual LOGS50 EN_MI_090221
1.
INSTALLING LOGS50
Make sure the working temperature it is within the boundaries of – 30ºC to
+85ºC. It is a wall mounting device with no need of additional accessories.
Device ingress protection: IP67 - IP68 depending on model. IP68 protection
for LOGS50 equipment is established in accordance with the following
criterion: depth in water up to 1 meter for a up to 2 hours.
If it is necessary to open the box, this must be always done in a dry
environment, so that when the device is closed there is no moisture inside.
Humidity in conjunction with abrupt thermal changes might cause damage in
the electronics.
Equipment performance might be altered during the installation process and
when manipulating. Next are shown critical aspects that must be kept under
controlled:
a.
Concerning the enclosure
: Ensure the enclosure is tightly closed.
The box is closed by making pressure on the lower part of the lid.
b.
Regarding the antennas:
Screw tightly the antenna to the RF
connector by using the proper wrenches.
c.
Regarding signal connectors
: Signal cables must go perfectly
screwed to the circular connector and where no cable be connected,
in its place, a cap must be firmly screwed on the connector.
QUICK GUIDE FOR INSTALLATION