The configuration of this input must be done using the third analog input fron the
application software- named as SENSOR in the picture.
Besides the internal pressure sensor, this model includes for external
connectivity, a connector for 4 digital inputs and two analog inputs (DI1I-AI1)
and a second connector for external power supply combined with Modbus RTU
serial channel (COM-POW).
1.5 INTERNAL PRIMARY OR RECHARGABLE BATTERIES
LOGS50 uses up to 4 lithium cells that allows it to work in an autonomous way.
These types of batteries are available in various formats and provide a nominal
voltage of 7,2 VDC power and current peaks up to 2 A. These batteries are high
capacity and high power and to keep this specified high performance only the
models that meet all these requirements should be used.
For rechargeable accumulators LOGS50 has circuitry for battery recharging.
The batteries are fixed to the base by clip holders and retainers. To change
batteries, please proceed following the next steps:
Withdraw the battery retainers if placed.
Extract the battery cells.
Wait 2 minutes before connecting the new batteries so the system can
properly reset.
Place the new battery cells in their place.
Check that LOGS50 led (LED DS1) blinks twice and the buzzer sounds
right after nearing the magnet to the place enabled.