MULTIFUNCTION REMOTE OPERATING INSTRUCTIONS
14
Using the Fireplace without a Remote Control
The fireplace can be turned ON (HI only) and OFF with the wall switch.
The fireplace flame ON/OFF is the only function that will operate;
no flame adjustment, light or blower will work when using the wall
switch. The wall control switch should be turned OFF when the fire-
place is not being used for extended periods of time.
Battery Backup Operation
Install batteries (See initialization sequence on page 12). In case of
power loss, the fireplace will switch to battery mode automatically.
The fireplace will operate normally without the fan or light control
when in battery mode.
Low Battery Detection
When the backup batteries are low, the module emits a double-beep
when it receives an on/off command. The system will not accept any
commands until the batteries are replaced or A/C power is restored.
Lockout State Definition
To prevent damage to the fireplace, IFC board will automatically lock-
out the remote control if it detects a anomalous flame or too many
unsuccessful ignition attempts. The lockout state will remain as long
as the power supplies are applied.
When the IFC board goes into lockout state:
1. Both the Pilot and the Main Burner solenoids in the gas valve are
de-energized;
2. A diagnostic code is sent through the diagnostic red LED.
3. The IFC board will ignore any burner ignition command and remain
in the OFF state unless the unlock command sequence is met.
Turn the system power supplies (to the wall control or remote control)
OFF for two or three seconds and then restore power. If the lockout
reoccurs, call your dealer. The causes of lockout must be investigat-
ed under safe conditions by trained service personnel.