background image

Owners &

Installation

Manual

Baltimore
Gas Fires

PLEASE KEEP THESE INSTRUCTIONS
FOR FUTURE REFERENCE

WARNING

Improper installation, adjustment, alteration,
service or maintenance can cause injury or
property damage.
For assistance or additional information
consult an authorized technichian, or your
Masport Gas Fire Dealer.

FOR YOUR SAFETY

Do not store or use gasoline or other
flammable vapours and liquids in the vicinity
of this appliance

Installation and service must be performed by
authorized personnel.

FOR YOUR SAFETY

What to do if you smell gas

Do not try to light any
appliance
Do not touch any
electrical switch
Do not use any phone
in your building
Immediately close the
shutoff valve behind the
heater
Call the technician




Metal Fab Industies Limited - New Zealand
PO Box 58 473
Greenmount
Auckland

Metal Fab PTY - Australia
Unit 2, 205 Abbotts Road
Dendenong South
Victoria 3175

591363

Summary of Contents for BALTIMORE ACC LP

Page 1: ...ore or use gasoline or other flammable vapours and liquids in the vicinity of this appliance Installation and service must be performed by authorized personnel FOR YOUR SAFETY What to do if you smell gas Do not try to light any appliance Do not touch any electrical switch Do not use any phone in your building Immediately close the shutoff valve behind the heater Call the technician Metal Fab Indus...

Page 2: ...LS COVERED ARE For use with Natural Gas BALTIMORE STD NG BALTIMORE ACC NG BALTIMORE RMT NG BALTIMORE ECS NG For use with Liquid Propane Gas LPG BALTIMORE STD LP BALTIMORE ACC LP BALTIMORE RMT LP BALTIMORE ECS LP STD Standard ACC Accessory RMT Remote ECS Electronic Control System ...

Page 3: ...d that you have your heater checked yearly by an Authorised Technician BEFORE INSTALLATION COMMENCES check the data plate on the rear of the heater cabinet to verify that it is the correct type to suit your gas and also that the gas consumption rate is correct for your application CONTENTS OPERATING INSTRUCTIONS 2 3 4 5 Cleaning instructions 6 INSTALLING INSTRUCTIONS 6 Heater dimensions 6 Minimum ...

Page 4: ...n the stove pedestal on either side at the rear facing forward to sense the signal from the remote control The remote control is battery powered and the receiver requires a 240v AC power source Instructions for fitting these optional thermostats are supplied with them LIGHTING THE PILOT ACC models Note To avoid the risk of backburning do not attempt to re light the fire less than three minutes aft...

Page 5: ...controlled by an internal switch which will not permit it to start until the fire is hot about ten minutes from cold on high fire and will keep it running for some time after the fire goes out PROGRAMMING THE REMOTE CONTROL The control can be programmed to operate the heater at a desired later time The controls for this are under the sliding cover below the display Programming instructions are in ...

Page 6: ...ome time after the fire goes out PROGRAMMING THE REMOTE CONTROL The control can be programmed to operate the heater at a desired later time The controls for this are under the sliding cover below the display Programming instructions are in the instruction sheet supplied with the remote control NOTE Occasionally the electrical system may lock up Turning off the mains supply for ten seconds will cle...

Page 7: ...is running turn it off either at the rotary switch or the wall socket STD models only Models fitted with internal switches will stop after the firebox has cooled To extinguish the pilot light on STD models press down on the control and turn it fully clockwise to the OFF position To extinguish the pilot light on ACC and RMT models press the PILOT control knob part way down and turn it fully clockwi...

Page 8: ...clogged with lint After a time the inside of the glass may require cleaning To do this carefully remove the three glass pieces See Glass Removal and Assembly page 12 and clean their inside surfaces with a non abrasive cloth and a non scratching type household cleaning liquid Replace the parts as detailed on page 12 keeping fingerprints off the inside glass surfaces No other user maintenance should...

Page 9: ... maintained at all times and sufficient room will be needed to facilitate servicing the heater Avoid positions where curtains or furniture might accidentally come too close to the heater Select a location where the gas supply can be installed readily An electrical outlet will also be required INSTALLING PROCEDURE SHIMS The glass panels are protected from shipping damage by paper shims fitted betwe...

Page 10: ...G or 2 5 kPa for LP care must be taken not to turn the plastic wheel as the knob is re fitted in its maximum anti clockwise position This position is set when the skirt of the knob contacting the adjacent metal up stand Rotate the knob clockwise and then fully anti clockwise while observing the pressure to verify that it is correct before replacing the retaining screw and re coupling the control r...

Page 11: ...rease the speed through all four fan speed settings three speeds and off while pressing the end will step it down through the speeds Verify correct operation FLUE USE ONLY AN APPROVED FLUE SYSTEM 1 Stand the heater in its proposed position taking care to observe the minimum clearances shown on page 7 The heater does not require a floor protector hearth 2 Drop a plumb bob from the ceiling to hang c...

Page 12: ...efore leaving the site If fitted open the gas supply valve at the rear of the heater and check all gas joints for leakage using a leak check solution or an electronic sniffer NOT a naked flame Test fire the heater following the lighting instructions on pages 2 3 and 4 of this manual First check that the pilot light ignites satisfactorily Initially it may take several attempts until the air is purg...

Page 13: ...nd the heater Remove the access plate on the rear of the cabinet Disconnect the gas line at the heater Lift the flue trim about 75mm and support it with a wooden block Slacken any flue clamp and lift the flue while moving the heater from beneath it Slide the heater away from the wall supporting the flue and trim on a suitable spacer Keep the heater upright at all times to avoid displacing the logs...

Page 14: ...to the heater Fit the spring first then the backing strip then the rope and finally the glass 8 Fit both side glasses in place so that their SMOOTH EDGES WILL BE AGAINST THE FRONT GLASS The front glass can then be fitted TAKING CARE THAT THE BEVELLED EDGES FACE THE FRONT i e away from the side glasses Offer the front glass into position with its lower edge just above the top of the bottom retainin...

Page 15: ...of the pilot the burners and the control valve by lighting the fire 8 Check the operation of the thermostat if fitted by turning the set temperature above and below the ambient room temperature and checking the response of the fire Other points which can be checked after completing the above are 1 Thermocouple generation 2 Gas consumption rate 3 Carbon dioxide content in the combustion products 4 ...

Page 16: ...NOTE If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard 14 ...

Page 17: ...ver indicator light Restore mains supply Fit new batteries Aim handpiece at receiver move closer to receiver Press start switch beside receiver Press reset switch at rear and try again Pilot will not light even though there is a strong blue spark Air in pilot pipeline Repeat starting attempts until air is cleared Incorrect lighting procedure Follow the instructions in this manual No gas supply at ...

Page 18: ...ogs being burned off Follow glass cleaning directions under Maintenance Instructions Fan hums but there is poor air circulation Dirty fan impeller Disconnect electrical power Remove fan and clean impeller Fan will not run STD models No power to fan Make sure the fan plug is firmly home and that fan switch is not in the OFF position Check whether the power socket works with another appliance Other ...

Page 19: ...ANNUAL SERVICE RECORD DATE SERVICE DETAILS SERVICED BY 17 ...

Page 20: ...s Fires are manufactured in New Zealand by MASPORT LTD 1 37 MT WELLINGTON HIGHWAY P O Box 14 349 Panmure Auckland New Zealand A G A Approvals MG 5000 01 NG and MG 5000 01 LP Certificate No 5656 Installed by Date ...

Reviews: