background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Massage chair structure

(pic 2)──Back of the chair 

 

Main Drive Component                                   

Backrest cylinder                                   

emergency switch                                   

Power switch component                                   

Transformer 
9660-A33X 

 

Power board 

 

Main board 

 

Power switch 

 

Power filter 

 

No 

  4A Fuse 

 

Controller connection 

 

Summary of Contents for Remidial Deluxe +

Page 1: ......

Page 2: ...structure II Main components Technical Specifications III Distribution and functions of the Power board Main boardpluggable unit IV Troubleshoot of the chair V Disassemblediagram of parts of the mecha...

Page 3: ...ure pic 1 Front of the chair Valve interposer airpump component Internal valve Valve interposer Waist twist component Shoulder massage component Footrest cylinder 3D massage mechanism medmemechanis m...

Page 4: ...tructure pic 2 Back of the chair Main Drive Component Backrest cylinder emergency switch Power switch component Transformer 9660 A33X Power board Main board Power switch Power filter No 4A Fuse Contro...

Page 5: ...Massage chair structure pic 3 Side of the chair Negative ions generator Negative ions board 12V Fan Negative ions keypad 7W Speaker...

Page 6: ...D motor Neck shoulder position potentiometer Bottom limit switch for 3D motor Flapping motor Flapping Simultaneous testing board Traveling testing board Width testing signal transfer board Kneading mo...

Page 7: ...Rated voltage 30 80 3D motor 62ZYT100 35G DC110V 30 80 Kneading Flapping Travling Butt ock swing motor 62ZYT100 36G DC110V 110 120 Air pump AC110V 100 150 Backrest cylinder DDG110V 450 260 AC110V Mai...

Page 8: ...AC220V White Black OutputAC110V Black black Output AC12V Blue Blue Output AC28V Transformer 9660 A33X RT AC110V 220V 240V 40 50 electromagnetic valve fanfold plug DC12V Traveling switch Touching switc...

Page 9: ...o Amplifier CON306 DC5VA 12V 5VB Power output Starting signal inlet CON305 shunt DC16V To negative ion CON303 transfer to main board AC28V 14VA CON307 shunt DC16V To LED light board CON104 AC110V Tran...

Page 10: ...electromagnetic valve CON32 foot part electromagnetic valve CON24 Hand shoulder electromagnetic valve CON19 power board inlet AC28V 14VA CON18 Heating AC28V output CON14 controller wire CON8 DC5VA 12...

Page 11: ...eck Pic 7 JY1905 Transformer 817 Optocoupler TL431 compensating pipe broken change power board Off Controller problem First check Pic 2 make sure the controller connection and wires good if still not...

Page 12: ...er have DC5V voltage By controller start it Starting signal through power board CON306 s JDQ control relay 105LM coil to make DC5V power Close Then CNON102 get AC220V Ringlike Transformer 9660 A33 get...

Page 13: ...ight power switch input to power indicator light DC5VA on PC board LED3 power indicator light power board 7805 stabilivolt input PC boardDC5VB power indicator light Pic 8 power indicator light on powe...

Page 14: ...t and output from optocoupler and we have to take care the optocoupler needs a DC 13V power to reach to drive signal orelse it cannot transport to drive tube field effect transistor 13N50C Figure 11 o...

Page 15: ...ed by the PC board The testing circuit has problem the single chip cannot give a sign First check the wire from CON45 to the limit switch on the track of the massage hand is it ok second check the lim...

Page 16: ...COM is NO is NC Figure 15 can test by multimeter test the buzzer gear Normal close NO often close contact will open Normal open NC often open contact will breakover Q7 move up signal paster 8050 audi...

Page 17: ...er it is in 30 80 if not in this range change a new motor The wire which connect with PC board and motors has problem See figure 13 check the wire through CON20 on PC board and stretch motor on massag...

Page 18: ...wer circuit is normal the problem was caused by 250 optocouple IR21091 paster integration or other components was broken caused short out change the components or PC board is ok First make sure there...

Page 19: ...heck the problem caused by cylinder or PC board with the normal cylinder to driving the abnormal cylinder if it can move we can judge the problem is caused by the PC board if it cannot move we can jud...

Page 20: ...pler 817 Audio 8050 Audio 8050 Fuse tube WH250 400 Audio 8050 Relay 212L Wire inside Circle testing board Stretch limit switch in cylinder Pic 22 components inside Pic 20 cylinder testing circuit diag...

Page 21: ...roken change the components or a new PC bboard When the power on the air pump work automatically canot stop Figure 25 and 26 silicon BCR5PM or audion 8050 was broken when the chair power on the PC boa...

Page 22: ...ke sure where is the trouble from air pump or solenoid valve when the airbag no working Generally you can judged by listening and touch because they are with noise or vibration when working normally P...

Page 23: ...al of the hip working situation so that cant give the inductor to go next step Motor damaged Doesn t work Repair or exchange the detect board Driver board damaged Detect the motor resistance value is...

Page 24: ...put pug ofphoto coupler 250 in low level no output with DC13V have output withDC5 8V that cause one of Field effect transistors 13N50C working pic 29 or 30 Motor damaged thermistor or Bad welding pic...

Page 25: ...No heating exchange damaged component or driver board Driver board no AC28V input or driver board damaged transformer damaged will no giving AC28V look at the driver board to detect the controlled sil...

Page 26: ...armrest pic 34 no music when used cell phone MP3 audio input signal damaged Music board damaged Power board damaged power board CON302 No giving DC16V see pic 5 Exchange the power board Audio wire da...

Page 27: ...t Driver board blue tooth and DC3 3V power plug reset restart signal Plug for magnetic valve output blue tooth signal input Plug for magnetic valve input Music signal MP3 audio signal input Power boar...

Page 28: ...n off button damaged Anion board anion generator damaged DC16V don t send the current to the anion board see pic 35 Switch board damaged Fan damaged Anion board damaged DC12V output no giving power bo...

Page 29: ...de light doest work Not full of light working Right light panel doest work Light Panel LED damaged Right light panel damaged Left light panel damaged because left one controlled by right one Power boa...

Page 30: ...disassemble diagram of parts of the mechanism 1 Armrest Used the wrench to dismantle the screw that marked in red see picture remove the armrest the hole of screw in armrest...

Page 31: ...parts of the mechanism 2 Hip swing component 1 remove the seat cushion 2 open the zip 3 dismantle the 4 units screw that fixed the button hip swing component 4 dismantle the full hip swing component...

Page 32: ...nism 3 calf 1 2 3 4 1 open the PU cover that connect the calf and seat 2 dismantle the protection cover of seat frame 3 dismantle the screw which fixed calf shaft 4 dismantle the calf parts from the c...

Page 33: ...ntle 4 units screw that inside of upper armrest side see picture above it already be marked on red 3 dismantle 2 units screw that outside of upper armrest bottom see picture it already be marked on re...