20
6. Programming
The signal decoder supports the
DCC-programming-modes CV
reading and writing as well as
PoM-switch-commands. With the
integrated electrical load, there
is no additional connection to
another consumer load necessary
in order to programm or read.
6.1 Programming lock CV 15/16
To prevent unintentional pro-
gramming this decoder offers
a programming lock in CV 15
/ 16. This works like a key and
lock procedure. If CV 15 (key)
matches CV 16 (lock) program-
ming is possible. If CV 15 ≠ CV 16
the programming lock is active.
We recommend to not change
the value of CV 16. If several
identical decoders are installed the
standard value CV 16 needs to be
changed. CV 15 will automatically
be changed to the new value of
CV 16. If the programming lock is
active and you do not remember
the value of CV 16, you may reset
the programmig lock with CV 8 =
16 to its factory default settings.
STANDARD VALUE CV 15/16
Standard Value CV 15/16 = 225
6. Programmierung
Der Signaldecoder unterstützt
die DCC-Programmierarten
CV lesen und schreiben sowie
PoM-Schaltbefehl. Durch eine
integrierte elektronische Last ist
zum Programmieren und Auslesen
kein zusätzlicher Anschluss eines
Verbrauchers erforderlich.
6.1 Programmiersperre CV15/16
Um ein versehentliches Program-
mieren zu verhindern bieten CV 15
und CV 16 eine Programmiersper-
re. Diese arbeiten wie Schlüssel
und Schloss. Nur wenn CV 15
(Schlüssel) = CV 16 (Schloss) ent-
spricht, kann man CV Werte ver-
ändern. Ist CV 15 ≠ CV 16, ist die
Programmiersperre aktiv. Der Wert
in CV 16 sollte nicht geändert wer-
den. Außer man verbaut mehrere
identische Decoder, dann muss
man CV 16 ändern. Wird CV 16
geändert, ändert sich automatisch
CV 15. Sollte die Programmier-
sperre aktiv sein und Sie wissen
den Wert von CV 16 nicht mehr,
so können Sie mit CV 8 = 16 die
Programmiersperre zurücksetzen.
STANDARDWERT CV 15/16
Standardwert CV15/16 = 225