Mastech MS6813 Multi Function Network Cable Tester
11
1.2
Coaxial Cable Testing
WARNING
TO AVOID ELECTRICAL SHOCK AND INJURY, UNPOWER THE CIRCUIT WHILE
PERFORMING TESTS.
Follow the steps:
a)
Connect one end of coaxial cable to transmitter BNC socket, another end to
remote BNC socket.
b)
Power on the Tester, power indicator is on.
c)
BNC indicator should be off. If the light is on, the network is miswired.
d)
Press “BNC” button on the transmitter, if coaxial cable indicator display green
light, the network connection in good condition, if the indicator display red light,
the network is miswired.
e)
Continuity Testing
WARNING
TO AVOID ELECTRICAL SHOCK AND INJURY, UNPOWER THE CIRCUIT WHILE
PERFORMING TESTS.
a)
Use function “CONT” on the transmitter to do the testing (to test both ends of cable
simultaneously). Turn the switch on the transmitter to “CONT” position; connect red
lead on the transmitter to one end of the target cable and black lead to the other end. If
the CONT indicator display
red
light, the cable continuity is in good condition.
(Network resistance lower then 10K
Ω
)
b)
Use “TONE” function on the transmitter along with the receiver (when both ends of
network cables are not copresent.) Connect the wire adaptor on transmitter to the