DIGITAL MULTIMETER
OPERATING INSTRUCTION NTS
4.15.2 Set the rotary selector to the
mV range
position.
4.15.3 Press the "SELECT" button to switch to DC
measurement. Then press the “RANGE” button to
choose the auto range or manual range mode.
4.15.4 Connect the test leads to the voltage source or load
terminals for measurement.
4.15.5 Take the reading on the main indicator of the LCD.
The polarity symbol denotes the polarity of the end
NOTE:
NOTE:
NOTE:
NOTE:
1) When the input is open, unsteady readings may
appear.
This is normal because the meter is highly
sensitive.
When the test leads contact the circuit, the
true reading will be shown.
2) At the manual range mode, when only ‘OL’ or ‘-OL’ is
shown on the LCD, it means the measurement has
exceeded the range.
A higher range should be
selected.
3) At the manual range mode, when the scale of the
value to be measured is unknown beforehand, set the
rotary selector to the highest range.
4.
4.
4.
4.1
1
1
16
6
6
6 MEASURING
MEASURING
MEASURING
MEASURING AC
AC
AC
AC MILLIVOLTAGE
MILLIVOLTAGE
MILLIVOLTAGE
MILLIVOLTAGE
4.16.1 Plug the black test lead into the COM jack and the
red test lead into the V jack.
4.16.2 Set the rotary selector to the
mV range
- 34 -
DIGITAL MULTIMETER
OPERATING INSTRUCTION NTS
position.
4.16.3 Press the "SELECT" button to switch to AC
measurement. Then press the “RANGE” button to
choose the auto range or manual range mode.
4.16.4 Connect the test leads to the voltage source or load
terminals for measurement.
4.16.5 Take the reading on the main indicator of the LCD.
NOTE:
NOTE:
NOTE:
NOTE:
1) When the input is open, unsteady readings may appear.
This is normal because the meter is highly sensitive.
When the test leads contact the circuit, the true
reading will be shown.
2) At the manual range mode, when only ‘OL’ or ‘-OL’ is
shown on the LCD, it means the measurement has
exceeded the range.
A higher range should be
selected.
3) Under the manual range mode, when the scale of the
value to be measured is unknown beforehand, set the
rotary selector to the highest range.
4.1
4.1
4.1
4.17
7
7
7 MEASURING
MEASURING
MEASURING
MEASURING DC
DC
DC
DC CURRENT
CURRENT
CURRENT
CURRENT
WARNING
WARNING
WARNING
WARNING
Beware
Beware
Beware
Beware of
of
of
of Electrocutio
Electrocutio
Electrocutio
Electrocution
n
n
n....
Turn
Turn
Turn
Turn off
off
off
off the
the
the
the power
power
power
power of
of
of
of the
the
the
the circuit
circuit
circuit
circuit to
to
to
to be
be
be
be measured
measured
measured
measured
before
before
before
before connecting
connecting
connecting
connecting the
the
the
the meter
meter
meter
meter to
to
to
to the
the
the
the circuit
circuit
circuit
circuit....
- 35 -