1.Overview

To avoid electrical shock or personal injury,
please read all safety information,warnings and 
precautions before using the meter.

The MS8238C is a small, safe and reliable 3 ½ digit 
handheld auto ranging multimeter.This meter can 
measure AC/DC voltage, AC/DC current, resistance, 
diode, continuity, battery test, temperature and 
non-contact voltage tests.This tool is ideal for 
professionals and hobbyists alike.

2.

 

Safety Information

2.1 Safety Standards

The MS8238C meets standards for CAT III 600V 
installations and a pollution degree of 2

.

• The protection provided by the meter can only be 
  ensured if all safety procedures are strictly followed.
• The safety symbols on the meter are to advise of 
  potential dangerous situations.Caution is required when 
  measuring close to the meter’s safety limits.
• Never exceed the protection limit values indicated in 
  the specifications for each range of measurement.

2.2 Precautions

• To avoid electrical shock or personal injury, observe and 
   follow all safety precautions
• Check the meter for damage before use.Do not use if 
   any damage is observed.
• Check the test leads for cracks or exposed wires before 
  using the meter.Replace if necessary.
• Ensure the meter works properly by testing a known 
  voltage source first.  If not working properly, the 
  protective equipment may be damaged; have the meter 
  serviced before using.
• Never measure voltages that may exceed the protection 
  limit indicated on the meter.
• Always be careful when working with voltages above 
  60V DC or 30V AC rms. Keep fingers behind the probe 
  barriers when making voltage measurements.
• Make sure the test leads are in the correct input jacks 
  before measurement.
• Do not expose the meter to explosive gas, dust or vapor.
• When connecting the test leads to a measurement 
  circuit, connect the common lead first, then the live lead.  
  Reverse when disconnecting.
• Turn off power to circuit and discharge all capacitors 
  before making resistance, continuity or diode 
  measurements.
• In order to avoid incorrect DC voltage readings, check 
  the circuit for AC voltage first, then put the meter in the 
  appropriate DC voltage range.
• Turn off circuit power and check fuses before connect 
  the leads when measuring current.Turn circuit power 
  on after making connection.
• Never use the meter unless the back cover is in place 
  and fastened securely.

The

 

special

 

attention

 

should

 

be

 

paid

 

when

 

using

 

the

 

meter

 

because

 

the

 

improper

 

usage

 

may

 

cause

 

electric

 

shock

 

and

 

damage

 

the

 

meter

 .

The

 

safety

 

measures

 

in

 

common

 

safety

 

regulations

 

and

 

operating

 

instruction

 

should

 

be

 

complied

 

with

 

when

 

using

In

 

order

 

to

 

make

 

fully

 

use

 

of

 

its

 

functions

 

and

 

ensure

 

safe

 

operations

 

please

 

comply

 

with

 

the

 

usage

 

in

 

this

 

section

 

carefully

.

WARNING

Summary of Contents for MS8238C

Page 1: ...al Digital Multimeter CAT III 600V MS8238C DIGITAL MULTIMETER Autorange Auto power off 9V 1 5V 12V FUNC HOLD RAN NCV 600V CAT III mA μA V TEMP mAμAV TEMP COM MAX 30 sec every 15 min MAX FUSED 10A MAX 200mA FUSED MAX 600V ...

Page 2: ...7 4 1 AC DC voltage measurement 7 4 2 AC DC current measurementrent 7 3 4 Auto Power Off Function 6 5 Specifications 11 5 1 General Specifications 11 5 2 Technical Specifications 12 4 3 Resistance measurement 8 4 4 Continuity measurement 9 4 5 Diode test 9 4 6 Battery test 10 4 7 Temperature measurement 10 6 Maintenance 15 6 1 General Maintenance 15 6 3 Replacing the Probe 16 6 2 Replacing the Bat...

Page 3: ... source first If not working properly the protective equipment may be damaged have the meter serviced before using Never measure voltages that may exceed the protection limit indicated on the meter Always be careful when working with voltages above 60V DC or 30V AC rms Keep fingers behind the probe barriers when making voltage measurements Make sure the test leads are in the correct input jacks be...

Page 4: ...mediately A protective device may be damaged If there is any doubt please have the meter inspected by a qualified technician 2 3 Electrical Symbols AC DC Both direct and Alternating Current Important safety information High voltage with danger Ground Double Insulation Class II safety equipment Fuse must be replaced as per the specification herein Accord with the related EU laws and regulations AC ...

Page 5: ... the non contact voltage detection Hold the meter up to a voltage source and the buzzer will sound and the NCV indicator will light up if voltage is detected Release the NCV button to stop NCV detection 3 4 Auto Power Off Function turn itself off To turn the meter back on press any button or turn the rotary switch to any position To deactivate the auto power off function hold down HOLD when turnin...

Page 6: ... test lead to either the input or 10A jack and the black lead to the COM jack Break the circuit and connect the leads in series with the circuit black lead on the lower voltage side Turn circuit power on and read the measurement on the display If OL is display it means the measurement has exceeded the current range Move the rotary switch to a higher range 4 3 Resistance measurement discharge Set t...

Page 7: ...ill display OL if the connection is reversed WARNING To prevent injury or damage to the meter turn off power to circuit and discharge all capacitors fully before making diode measurements 4 6 Battery test Connect the red test lead to the input jack and the black lead to the COM jack Connect the red test lead to the positive end and the black lead to the negative end of the battery and read the mea...

Page 8: ...dication Display shows OL Low Battery Indication Temperature coefficient 0 1xaccuracy C 18 C or 28 C 5 2 Technical Specifications Accuracy of reading digits at 18 C 28 C with a relative humidity of 80 guaranteed for a period of one year Resolution Accuracy 2V 20V 0 01V 0 001V 5 2 2 AC Voltage Measuring range 0 5 of reading 5 digits 5 2 1 DC Voltage Input impedance 10MΩ Max input voltage 600V DC or...

Page 9: ...AC rms Display shows forward voltage drop Function Description Resolution 1 5V Diode Test Rang 1mV 20mA 200mA 10A 0 01mA 0 1mA 10mA Overload protection mA jack FF 400mA H 600V fuse 10A jack FF 10A H 600V fuse Max input current mA jack 200mA DC 10A jack 10A DC When measuring current exceeding 2A do not measure for longer than 2 minutes continuously Wait 10 minutes to continue measurement 5 2 7 AC C...

Page 10: ... C 1 C 1 F 4 1382 F Position 2 0 of reading 2 digits Overload protection FF 400mA H 600V fuse 5 2 9 Battery Test Resolution Accuracy 12V 0 01V 0 01V 9V Position 0 8 of reading 7 digits 1 5V 0 001V 0 8 of reading 7 digits 3 0 of reading 5 digits Overload protection FF 400mA H 600V fuse 2 0 of reading 4 digits 6 2 Replacing the Battery and Fuses 6 3 Replacing the Probe 1 Under normal conditions it i...

Page 11: ...R 00 05 1568 ...

Reviews: