5
BEM/BEL SERIES
ENDLESS REMOTE GLASS DOOR MERCHANDISERS
WITH BOTTOM MOUNTED COIL
REQUIRED CONDENSING UNITS
NO. OF
DOORS
+35°F AVERAGE PRODUCT TEMP.
+20°F SUCTION
75°F AIR CONDITIONED STORE
55% RELATIVE HUMIDITY
-3°F AVERAGE PRODUCT TEMP.
-11°F SUCTION
75°F AIR CONDITIONED STORE
55% RELATIVE HUMIDITY
-12°F AVERAGE PRODUCT TEMP.
-18°F SUCTION
75°F AIR CONDITIONED STORE
55% RELATIVE HUMIDITY
COND. UNIT REQUIRED FOR AIR
TEMP. ENTERING CONDENSER*
COND. UNIT REQUIRED FOR AIR
TEMP. ENTERING CONDENSER*
COND. UNIT REQUIRED FOR AIR
TEMP. ENTERING CONDENSER*
90°F
100°F
110°F
90°F
100°F
110°F
90°F
100°F
110°F
2
MHHX0061B
MHHX0061B
MHHX0061B
MHLZ0071
MHLZ0071
MHLZ0071
MHLZ0091
MHLZ0091
MHLZ0091
3
MHHX0061B
MHHX0061B
MHHX0061B
MHLZ0071
MHLZ0091
MHLZ0091
MHLZ0091
MHLZ0121
MHLZ0121
4
MHHX0061B
MHHX0081B
MHHX0081B
MHLZ0091
MHLZ0091
MHLZ0121
MHLZ0121
MHLZ0121
MHLZ0121
5
MHHX0081B
MHHX0081B
MHHX0111
MHLZ0091
MHLZ0121
MHLZ0121
MHLZ0121
MCLZ0141
MCLZ0171
6
MHHX0111
MHHX0111
MHHX0111
MHLZ0121
MHLZ0121
MCLZ0141
MCLZ0141
MCLZ0171
MDLZ0201
7
MHHX0111
MHHX0111
MHHX0151
MHLZ0121
MCLZ0141
MCLZ0171
MCLZ0171
MDLZ0201
MDLZ0201
8
MHHX0151
MHHX0151
MHHX0151
MCLZ0141
MCLZ0171
MCLZ0171
MDLZ0201
MDLZ0201
MDLZ0231
9
MHHX0151
MHHX0151
MHHX0191
MCLZ0171
MCLZ0171
MDLZ0201
MDLZ0231
MDLZ0231
MDLZ0291
10
MHHX0151
MHHX0191
MHHX0191
MCLZ0171
MDLZ0201
MDLZ0231
MDLZ0231
MDLZ0291
MDLZ0291
11
MHHX0191
MHHX0191
MHHX0221
MDLZ0201
MDLZ0231
MDLZ0231
MDLZ0291
MDLZ0291
MDLZ0331
12
MHHX0191
MHHX0221
MHHX0221
MDLZ0231
MDLZ0231
MDLZ0291
MDLZ0291
MDLZ0291
MDLZ0331
13
MHHX0191
MHHX0221
MHHX0251
MDLZ0231
MDLZ0291
MDLZ0291
MDLZ0291
MDLZ0331
BCLZ0750
14
MHHX0221
MHHX0251
MHHX0251
MDLZ0291
MDLZ0291
MDLZ0291
MDLZ0331
BCLZ0750
BCLZ1000
15
MHHX0251
MHHX0251
MHHX0301
MDLZ0291
MDLZ0291
MDLZ0331
BCLZ0750
BCLZ0750
BCLZ1000
16
MHHX0251
MHHX0251
MHHX0301
MDLZ0291
MDLZ0331
BCLZ0750
BCLZ0750
BCLZ1000
BCLZ1000
17
MHHX0251
MHHX0301
MHHX0351
MDLZ0291
MDLZ0331
BCLZ0750
BCLZ1000
BCLZ1000
BCLZ1000
18
MHHX0301
MHHX0301
MHHX0351
MDLZ0331
BCLZ0750
BCLZ1000
BCLZ1000
BCLZ1000
BCLZ1000
19
MHHX0301
MHHX0351
MHHX0351
BCLZ0750
BCLZ0750
BCLZ1000
BCLZ1000
BCLZ1000
BCLZ1000
20
MHHX0301
MHHX0351
MHHX0441
BCLZ0750
BCLZ1000
BCLZ1000
BCLZ1000
BCLZ1000
BCLZ1500
21
MHHX0351
MHHX0351
MHHX0441
BCLZ0750
BCLZ1000
BCLZ1000
BCLZ1000
BCLZ1000
BCLZ1500
22
MHHX0351
MHHX0441
MHHX0441
BCLZ1000
BCLZ1000
BCLZ1000
BCLZ1000
BCLZ1500
BCLZ1500
23
MHHX0351
MHHX0441
MHHX0441
BCLZ1000
BCLZ1000
BCLZ1000
BCLZ1000
BCLZ1500
BCLZ1500
24
MHHX0441
MHHX0441
MHHX0441
BCLZ1000
BCLZ1000
BCLZ1000
BCLZ1500
BCLZ1500
BCLZ1500
25
MHHX0441
MHHX0441
MHHX0501
BCLZ1000
BCLZ1000
BCLZ1000
BCLZ1500
BCLZ1500
BCLZ1500
*Condensing unit and line size based on 100' line run.
See the Master-Bilt
Condensing Unit & Refrigeration Systems I/O Manual
for other conditions.
For other than high capacity condensing units, consult factory.
Use this chart to determine the correct condensing unit for your endless lineup.
Unless already indicated, add suffix "B" for one phase or "C" for three phase model.