MASTER-BILT PART LIST 

 
The table below gives Master-Bilt part numbers.  Use this chart when ordering replacement parts for your 

BMG/TMG 

cabinets. Always Advise Cabinet Serial Number When Ordering Parts 
 

Description 

BMG/TMG-27 

BMG/TMG-48 

BMG/TMG-52 

BMG/TMG-74 

BMG/TMG-80 

Accumulator 

09-00812 

09-00813 

09-00813 

09-00812 

09-00812 

Ballast 

23-01709 

23-01704 

23-01704 

23-01704 

23-01704 

Bulb 

23-01575 

23-01575 

23-01575 

23-01575 

23-01575 

Lamp Holder 

23-50562 

23-50562 

23-50562 

23-50562 

23-50562 

Capillary Tube 

11-01450 

11-01450 

11-01450 

11-01450 

11-01450 

Condensate Heater “B”  

17-00380 

 

 

 

 

Condensate Heater “T” 

17-00421 

17-00421 

17-00421 

17-00421 

17-00421 

Compressor “B” 

03-50330 

03-50330 

03-50330 

03-14901 

03-14901 

Compressor “T” 

03-50330 

03-50330 

03-50330 

03-14901 

03-14901 

Condensing Coil “B” 

07-13253 

07-13253 

07-13253 

07-13296 

07-13296 

Condensing Coil “T” 

 

 

 

 

 

Door-L.H. 

31-02491 

31-02492 

31-02513 

31-02492 

31-02513 

Door R.H. 

 

31-02493 

31-02514 

 

 

Door Trim 

29-01379 

29-01379 

29-01379 

29-01379 

29-01379 

Drier 

09-09309 

09-09309 

09-09309 

09-09309 

09-09307 

Evaporator Coil 

07-13293 

07-13293 

07-13293 

07-13311 

07-13311 

Evaporator Fan Blade 

15-13106 

15-13106 

15-13106 

15-13106 

15-13106 

Evaporator Fan Guard 

25-01324 

25-01324 

25-01324 

25-01324 

25-01324 

Evaporator Fan Motor 

13-13181 

13-13181 

13-13181 

13-13181 

13-13181 

Female Door Plug 

21-00568 

21-00568 

21-00568 

21-00568 

21-00568 

Leg “T” 

27-00558 

27-00558 

27-00558 

27-00558 

27-00558 

Light Switch 

19-13118 

19-13118 

19-13118 

19-13118 

19-13118 

Pilaster 

200I166XX 

200-16156C 

200-16156C 

200-16156C 

200-16156C 

Power Cord “B”  120/15A 
                           220/15A 

21-01201 

21-01201 

21-01201 

21-01513 
21-01243 

21-01513 
21-01243 

Power Cord “T”  120/15A 
                           220/15A 

21-01454 

21-01454 

21-01454 

21-01454 
21-01243 

21-01454 
21-01243 

Electronic Control 

19-14243 

19-14243 

19-14243 

19-14243 

19-14243 

Temperature Sensor T1 

19-14244 

19-14244 

19-14244 

19-14244 

19-14244 

Temperature Sensor T2 

19-14245 

19-14245 

19-14245 

19-14245 

19-14245 

External Relay 

19-14284 

19-14284 

19-14284 

19-14284 

19-14284 

Thermometer 

44-00963 

44-00963 

44-00963 

44-00963 

44-00963 

14-1/16” X 45” 

 

25-01296 

 

25-01296 

 

15-7/8” X 45” 

25-01294 

 

25-01294 

 

25-01294 

18-3/4” X 45” 

 

25-01295 

25-01295 

25-01295 

25-01295 

 
Accessories  

 

Description 

BMG/TMG-27 

BMG/TMG-48 

BMG/TMG-52 

BMG/TMG-74 

BMG/TMG-80 

Baskets (Cantilever) 

 

A200-16600 

A302-16600 

A200-16600 

A302-16600 

Casters (4) 3” Diameter 

A200-11140 

A200-11140 

A200-11140 

 

 

Casters (6) 3” Diameter 

 

 

 

A212-11140 

A212-11140 

Legs 6” 

A200-11170 

A200-11170 

A200-11170 

A212-11170 

A212-11170 

Shelves (Cantilever) 

33-01473 

33-01474 

33-01475 

33-01474 

33-01475 

 
 
 

Summary of Contents for BMG-27

Page 1: ...1 BMG TMG 27 48 52 74 80 LAE CONTROLLER Installation Operations Manual Master Bilt Products 908 Highway 15 North New Albany MS 38652 Phone 800 684 8988 PN 075 90000 Rev 4 26 11 ...

Page 2: ...2 ...

Page 3: ...ing Damage 6 INSTALLATION INSTRUCTIONS 6 General Instructions 6 Mechanical 6 Electrical 7 Leg and Condensate Pan Installation 8 Doors 8 ELECTRONIC CONTROLLER 9 10 SERVICE INSTRUCTIONS 11 TEMPERATURE SENSORS AND FAN MOTOR REPLACEMENT 12 FINAL CHECK LIST 12 MASTER BILT PART NUMBERS 13 ACCESSORIES 13 SALE AND DISPOSAL 14 WIRING DIAGRAMS BMG TMG 15 17 ...

Page 4: ...This space will allow for the circulation of air behind the case which will prevent condensation on the exterior surfaces NOTICE Read this manual before installing your cabinet Keep the manual and refer to it before doing any service on the equipment Failure to do so could result in personal injury or damage to the cabinet DANGER Improper or faulty hook up of electrical components on the refrigera...

Page 5: ...rds are used in the warnings and safety messages DANGER Severe injury or death will occur if you ignore the message WARNING Severe injury or death can occur if you ignore the message CAUTION Minor injury or damage to your cabinet can occur if you ignore the message NOTICE This is important installation operation or service information If you ignore the message you may damage your cabinet The warni...

Page 6: ...ime 6 When replacing burned out fluorescent tubes be sure that the electrical power to the lighting circuit is turned off NOTICE TO STORE OWNERS MANAGERS Moisture or liquid around or under the cabinet is a potential slip fall hazard for persons walking by or working in the general area of the cabinet Any cabinet malfunction or housekeeping problem that creates a slip fall hazard around or under th...

Page 7: ...r size Check power supply for low voltage If voltage reads 120 with no load and it drops below 100 or less when the compressor tries to start it is an indication of too small supply wiring or too long to run It is recommended that a separate circuit be run for each cabinet to prevent another appliance blowing the fuse or breaker causing loss of product IMPORTANT This cabinet is pre wired internall...

Page 8: ... is located directly under cabinet drain DOORS The BMG TMG cabinets have Anthony glass doors that are equipped with a patented TorqueMaster hinge system The doors are easily adjusted using a flathead screwdriver Fig 3 Figure 4 GRILL To remove the door shipping clamps remove the 4 shipping screws from the grill and remove the screws from the clamps Fig 4 and replace grill Torque Adjustment Leveling...

Page 9: ... display layout The compressor will be cycled off when the actual box temperature reaches its set point The Thermostat output indicator will be off Fan The fans will run constantly for BMG TMG cooler application The Evaporator fan will also cut off when the evaporator temp is above the fan stop temperature setting Defrost The control uses off cycle defrost for the BMG TMG cooler MANUAL DEFROST Def...

Page 10: ...AL CONNECTIONS The controller is provided with a screw terminal block to connect cables with a cross section up to 2 5 mm 2 Before connecting cables make sure the power supply complies with the control s requirements Separate the probe cables from the power supply cables the outputs and the power connections Do not exceed the maximum current allowed on each relay in case of heavier loads use a sui...

Page 11: ...gerant undercharged C Leak in system 3 Pressure normal cabinet warm A Coil blocked with frost see 4 B Refrigerant undercharged C Control set too warm 4 Cabinet not cycling coil blocked with frost A Defective temperature controller B Refrigerant overcharged C Location too hot D Condenser clogged E Condenser fan motor defective 5 Compressor starts and runs but cycles on overload A Low voltage B Rela...

Page 12: ...the zone sensor Insert the sensor for defrost termination firmly into the evaporator coil in between the fins Make sure the sensor wires do not touch or are not close to any heater rods To change fan motor disconnect fan motor leads remove screws from fan guards and motor mounts FINAL CHECK LIST A Check operating pressures B Check electrical requirements of unit to supply voltage C Set temperature...

Page 13: ...6 Evaporator Fan Guard 25 01324 25 01324 25 01324 25 01324 25 01324 Evaporator Fan Motor 13 13181 13 13181 13 13181 13 13181 13 13181 Female Door Plug 21 00568 21 00568 21 00568 21 00568 21 00568 Leg T 27 00558 27 00558 27 00558 27 00558 27 00558 Light Switch 19 13118 19 13118 19 13118 19 13118 19 13118 Pilaster 200I166XX 200 16156C 200 16156C 200 16156C 200 16156C Power Cord B 120 15A 220 15A 21 ...

Page 14: ...aster Bilt at 800 684 8988 The customer service department at Master Bilt should be contacted at the time of sale or disposal of your cabinet so records may be kept of its new location If you sell or give away your Master Bilt cabinet and you evacuate the refrigerant charge before shipment Master Bilt recommends that the refrigerant charge be properly recovered in compliance with section 608 of th...

Page 15: ...15 ...

Page 16: ...16 ...

Page 17: ...17 ...

Reviews: