ELECTRICAL
WARNING
Before servicing electrical components in the case make sure all power to case is off. Always use a qualified
technician.
STARTING PROCEDURE
1.
Start compressor and allow the case to pull down to 42 degrees or below before placing product into the OAM
.
2.
Check that the compressor cycles off and back on at least once.
FINAL CHECK LIST
A.
Check that the evaporator drain line is properly connected.
B.
All shelves are properly installed.
C.
All LED light bars are properly secure to the bottom of the shelf and plug to the cabinet’s back wall.
D.
Check electrical supply voltage to make sure it is in range.
E.
All loose items and debris is removed from inside of unit and lower equipement compartment.
F.
Check condensing unit for vibrating or rubbing tubing. Dampen and clamp as required.
G.
Check that the temperature inside of the case is between 35 and 42 degrees.