2/20 Rev. A 57-02694
4
INTRODUCTION
This manual contains important instructions for installing, using, and servicing a flammable refrigerant glass door
freezer merchandiser case, GFP-HG. Failure to properly install, use, or service this product could cause damage to
cabinet, explosion, fire, injuries and even death. A parts list is included with this manual. Read all these documents
carefully before installing or servicing your equipment.
STORE CONDITIONS
The GFP-HG are designed to operate in the controlled environment of an air-conditioned store. The store
temperature should be at or below 75
°
F and a relative humidity of 55% or less. At higher temperature or humidity
conditions, the performance of these cases may be affected and the capacity diminished.
The GFP-HG should not be positioned where it is directly exposed to rays of sun or near a direct source of radiant
heat or airflow. This will adversely affect the case and will result in poor performance.
If this case is to be located against a wall, there should be at least 6” space between the wall and the back of the
case. This space will allow for the circulation of air behind the case, which will prevent condensation on the exterior
surfaces.
DANGER
Risk of fire or explosion. Flammable refrigerant used. Consult instruction
manual/repair manual/owner’s guide before attempting to install or service this
product. All safety precautions must be followed.
DANGER
Improper or faulty hook-up of electrical components on the refrigeration units can
result in severe injury or death.
NEVER use an extension cord to power these units. All electrical wiring hook-ups must be done in
accordance with all applicable local, regional or national standards.
NOTICE
Installation and service of the refrigeration and electrical components of the cabinet
must be performed by a refrigeration mechanic and/or a licensed electrician.
The portions of this manual covering refrigeration and electrical components contain technical instructions intended
only for persons qualified to perform refrigeration and electrical work.
This manual cannot cover every installation, use or service situation. If you need additional information, call or write
our customer service Department.