7
LOADING
Do not place product in the case until 2 hours after it
is started. Stock cases as quickly as possible,
exposing only small quantities to store temperatures
for short periods of time. It is important to keep stock
rotated properly so that older stock does not
accumulate. A “First-In, First-Out” rotation practice
will keep the products in good salable condition.
Avoid loading the case so that product sticks out
beyond the shelves or blocking the return air grille at
the bottom of the case. This will interfere with the air
flow of the case and will result in diminished
performance.
PLACING PRODUCT IN THE CABINET
Do not load the cabinet with product to the point that the air discharge grille, air intake grille, or the air curtain created
by the discharge air, is blocked. The following diagram shows proper loading.
All units come with 14” shelves sufficient to have 3 levels.
CLEANING
To avoid electrical shock, turn the power off before cleaning.
The QMVM series cabinets are designed so that spills will accumulate in a drain pan. The drain pan is located
underneath the return air grill. Be sure to clean all areas with a mild detergent and water periodically.