background image

908 Highway 15 North • New Albany, MS 38652
PHONE: 800-647-1284 or 662-534-9061 • FAX: 800-232-3966 or 662-534-6049 • www.master-bilt.com

QMVM-L SERIES

QUANTUM SERIES MEDIUM TEMP LOW PROFILE 

OPEN DISPLAY MERCHANDISERS

TECHNICAL SPECIFICATIONS

1082-1/12-web

©Master-Bilt Products division of Standex International, Inc. All rights reserved. Printed in U.S.A.

All specifications subject to change without notice.

LISTINGS

HOOKUP

BID SPECIFICATIONS

Item no. QMVM-_______L
Provide__________(         ) Quantum Series 
Medium Temp Low Profile Open Display 
Merchandiser(s), Master-Bilt model no. 
QMVM-_______L.

Merchandiser to be constructed of 24 gauge 

painted textured galvanized steel interior and 
exterior and will be equipped with an elec-

Electrical hookup:  115v 
Plumbing hookup:  Requires connection 
 

to customer’s drain

tronically controlled monitoring system. 

Merchandiser to have two-position 

shelves adjustable in 1" increments, perfo-
rated interior back wall, independent shelf 
lighting and price tag molding. Merchan-
diser will also contain 2" foamed-in-place 
“zero ODP” urethane insulation. 

The refrigeration system is to be self-

contained, with front condenser air intake 
and rear air discharge and use R-134a refrig-
erant. The temperature range is 34° to 41°F 
(1° to 5°C). Merchandiser to have standard 
limited three year extended compressor 
warranty and two year limited parts and 
labor warranty. It is also to be UL and C-UL 
listed and UL EPH classified.

RECOMMENDED OPERATING CONDITIONS

• Merchandisers designed to hold product  

in the 34° to 41°F (1° to 5°C) range

• Designed to operate in air-conditioned 

stores where the maximum temperature is 
75°F and the maximum relative humidity 
is 55%

• Should not be installed in direct sunlight

• Should not be installed near HVAC vents, 

fans or doorways that will disrupt airflow  
and compromise the function of the air 
screen inside the case

• Bottom shelf should not be loaded such 

that the front air intake is obstructed

• Floor drain should be properly trapped

• Factory installed controls should not 

be altered, removed or replaced without 
consent of the factory

• Product must not be displayed in the cold 

air curtain 

MODEL

DIMENSIONS

(in.)

DIMENSIONS

(mm)

VOLTS

AMPS*

UNIT

H.P.

NO. OF

SHELVES

STANDARD

SHELF 

SIZE 

(in inches)

CAP.

CU. 

FT.

SHIP

CU. 

FT.

SHIP

WT.

LB/KG

L

D

H

L

D

H

QMVM-36L

36

30

60

914

762 1524

115

14.8

1/2

2

14 x 31

1

/

8

11.2

67.0

490/223

QMVM-48L

48

30

60

1219 762 1524

115

14.9

3/4

2

14 x 43

1

/

8

15.4

81.0

580/264

*If condensate evaporator pan accessory is used, it must be field installed 
and requires a dedicated 20 amp, 120 volt circuit.

PLAN VIEW

SIDE VIEW

ELEVATION VIEW

NEMA 5-20P

Reviews: