Evaporative Cooling

Evaporative cooling is nature’s way of cooling. When air is moved 
over a wet surface, water is evaporated and heat is absorbed.  When 
stepping out of a swimming pool with the wind blowing, evaporative 
cooling makes you feel cool, even though the air may be warm.  
The human body itself is cooled primarily by the evaporation of 
perspiration.

Vea el Español en el interior

110522-3

11-11

www.championcooler.com

EVAPORATIVE COOLER

Models

MMBT12
MMBT14

This unit works on the same principle.  Air is drawn across wet 
fi lter pads where the air is cooled by evaporation and then circulated 
throughout the building.  It is this combination of cooled air and the 
movement of air over the skin which makes it feel cool.

Unlike refrigeration systems which recirculate the air, an evaporative 
cooler continually brings in fresh air while exhausting old air.  You 
are completely replacing the air every 2 to 4 minutes by opening 
windows or doors or a combination of both.  The air is always fresh, 
not stale, laden with smoke and odors as happens with refrigerated 
air conditioning.

Summary of Contents for MMBT12

Page 1: ...e warm The human body itself is cooled primarily by the evaporation of perspiration Vea el Español en el interior 110522 3 11 11 www championcooler com EVAPORATIVE COOLER Models MMBT12 MMBT14 This unit works on the same principle Air is drawn across wet filter pads where the air is cooled by evaporation and then circulated throughout the building It is this combination of cooled air and the moveme...

Page 2: ...e float as shown if attaching a garden hose to the unit A 1 4 inch water line may also be used to supply a continuous amount of water to the unit Fill pan with water You may fill the pan manually for up to 3 hours of cooling For automatic filling you may attach a garden hose to the garden hose adapter or a 1 4 inch water line to the float valve Note Do Not Overfill Fill water to a maximum height o...

Page 3: ... and will deliver substantially more cool air Check belt and belt tension This applies only to model MMBT14 which is belt driven Model MMBT12 has a direct drive motor Check the belt for any cracks or wear and replace if necessary Check the tension on the belt A 3 lb force should deflect the belt 3 4 inches see Fig 4 Readjust belt if needed Clean pump Cleaning the pump is necessary once a year at s...

Page 4: ...logged Pump not working properly 1 Float arm not adjusted properly 2 Drain assembly leaking 1 Check power Replace fuse Reset breaker Plug in cords or replace if damaged 2 Adjust belt tension 3 Determine cause of overheating Adjust belt tension Oil blower bearings 4 Replace motor 1 Open windows or doors to increase air flow 2 Adjust belt tension or replace if needed 3 Replace pads 1 Open windows or...

Page 5: ... 001 30 Pump Mount Montura De La Bomba 222175 006 218001 031 31 Pump Retainer Sujetador De La Bomba 110714 32 Tube Water Delivery Tubo De Agua 310716 310716 33 Water Distributor Assembly Sistema Del Distribuidor De Agua 3D 15 3D 3 34 Holder Water Distributor Soporte Para El Distribuidor De Agua 110574 3 35 Drain Assembly Montaje De Desagüe 3DA 1 3DA 1 36 Float Valve Válvula De Flotador FL C FL C 3...

Page 6: ...6 110522 3 Parts Drawing Dibujo De Piezas MMBT12 ...

Page 7: ...7 110522 3 Parts Drawing Dibujo De Piezas MMBT14 ...

Page 8: ...cuando posible Esta baja velocidad del ventilador permite que el aire se queda más de largo en los filtros mojados y de tal modo produce un aire más fresco Los posiciones HIGH VENT y LOWVENT Ajuste el interruptor a la posición HIGH VENT alta o LOW VENT baja para poner en marcha el ventilador a una alta o baja velocidad sin la bomba Este es útil en noches frescas o cuando se desea un ventilador sol...

Page 9: ...ste la correa si es necesario Compruebe el correa para saber si hay grietas o desgaste y reemplácela si es necesario Fig 4 3 Libras 3 4 Pulgadas Cambie los filtros Debe cambiar los filtros una o dos veces durante cada temporada según la duración de ésta Al principio y a mediados de la temporada un filtro limpio es más absorbente y eficiente y producirá un mayor volumen de aire frío Limpie la bomba...

Page 10: ...place el cable 2 Ajuste la tensión de la correa 3 Determine la causa Ajuste la tensión de la correa Lubrique los cojinetes 4 Cambie el motor 1 Abra las ventanas o las puertas para aumentar el flujo de aire 2 Ajuste la tensión o cambie la correa 3 Cambie los filtros 1 Abra más las ventanas o puertas 2 Revise la distribución de agua Cambie los filtros Acomode la paja en el filtro Límpielos Cámbiela ...

Page 11: ...sponsables por daños que resulten a consecuencia de alguna falla de funcionamiento No somos responsables por cualquier daño producido por el uso de suavizadores de agua productos químicos materiales desincrustantes envolturas de plástico o si se usa en esta unidad un motor de mayor potencia de la que se indica en la placa de número de serie No somos responsables por el costo del servicio para diag...

Page 12: ...Champion Cooler Essick Air Products 5800 Murray St Little Rock AR 72209 1 800 643 8341 ...