background image

3 | 

P a g e

 

Helios 75K Floodlight System – User Manual 

”READ ALL INSTRUCTIONS” – Failure to follow the SAFETY 

RULES listed below and other safety precautions, may result in 

serious personal injury.

 

 

Operation and Care

 

 

 

Ensure the cover of the light panel 

is tightly fastened.

  If loose, water 

may enter the enclosure and cause 

damage to the lighting components. 

These are factory torqued to 60 in-

lb.

 

 

Ensure all cord connectors are free 

of moisture and are clean before 

making connections.

  Dirt or 

moisture may cause the light to 

malfunction and/or may decrease the 

life expectancy of the components.  

 

Handle, package, and use all 

components with care.  

The lens of 

the light panel is made of an impact-

resistant plastic but can fracture if 

struck with excessive force causing a 

hazard and/or Foreign Material risk. 

 

Do not position the light panel in 

close proximity to moving, 

mechanical equipment.

  Temporary 

and/or permanent damage to the 

components may occur if struck, 

reducing performance of the light or 

rendering it inoperable. 

 

Service

 

 

Disconnect plug 

from Power 

Console before 

performing any assembly, adjustment or 

repair to avoid possible injury. 

 

 

Service and/or repair must be 

performed only by Master-Lee 

personnel with the exception of 

lens replacement.

  Service or 

maintenance performed by 

unqualified personnel may result in 

incorrect reassembly which could 

cause serious hazard.

 

 

Do not remove the cover of the 

Power Console.

  Removal of the 

cover increases the risk of damage to 

internal components and electrical 

shock to personnel.

 

 

Lens and O-Ring shall be replaced 

with the manufacturer specified 

parts as outlined in this document.

  

Failure to use the specified parts may 

lead to product failure.

 

 

Decontamination or cleaning of the 

lighting assembly shall be 

performed with care.

  Hand-

washing with wet rags or a mild 

cleaning solution may be performed 

on the lighting assembly and cord. 

Use of pressure applied water may 

damage the components.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SAVE THESE INSTRUCTIONS! 

Summary of Contents for D3183

Page 1: ...650 Phone 724 539 8060 Fax 724 805 0079 www MasterLee com MASTER LEE ENGINEERED PRODUCTS INC H HE EL LI IO OS S 7 75 5K K F FL LO OO OD DL LI IG GH HT T S SY YS ST TE EM M U US SE ER R M MA AN NU UA A...

Page 2: ...81 Latrobe PA 15650 Phone 724 539 8060 Fax 724 805 0079 www MasterLee com MASTER LEE ENGINEERED PRODUCTS INC HELIOS 75K FLOODLIGHT SYSTEM U US SE ER R M MA AN NU UA AL L Document Number EDS 18 110 Par...

Page 3: ...elios 75K Floodlight System User Manual Table of Contents 1 Safety 2 2 Electrical Requirements 4 3 Inspection 4 4 Operation Instructions 5 5 Lens O Ring Replacement 6 6 Parts List 7 7 Technical Specif...

Page 4: ...s hazards and or damage to the equipment Do not expose the Power Console to wet environments Water entering the Power Console will increase the risk of electric shock Never use the cord of the Power C...

Page 5: ...Temporary and or permanent damage to the components may occur if struck reducing performance of the light or rendering it inoperable Service Disconnect plug from Power Console before performing any a...

Page 6: ...tely transparent Discoloration of the lens may indicate embrittlement due to excessive radiation exposure Inspect all bracket and lens cover fasteners for signs of degradation damage or wear Failure t...

Page 7: ...or downwards on the cable Injury to personnel may occur IF the energized panel is touched while operating Allow a minimum of 15 minutes for the light panel to cool down prior to handling 4 2 Instruct...

Page 8: ...turning OFF the light panel 4 4 1 Depress the Power I O rocker switch to turn off the light 4 4 2 Verify the panel is not emitting light 4 4 3 Unplug the power cord from the electrical outlet 4 4 4 Al...

Page 9: ...ce and or the potential risk of hazard or injury to personnel Part No Description Provided w System Quantity D3183 Helios 75K Drop Floodlight System includes the following items n a 1 D3184 Helios 75K...

Page 10: ...Power Console 13 x 11 x 3 12 lbs Light Output Up to 78 000 Lumens Light Color Temperature 5000K white light LED Life 50 000 hours 70 lumen output Radiation tolerance Approved for extended use in React...

Reviews: