background image

7 | 

P a g e

 

Helios 75K Floodlight System – User Manual 

6.

 

P

ARTS 

L

IST

 

Failure to use replacement parts as identified herein or as 

recommended by the manufacturer may result in reduced performance 

and/or the potential risk of hazard or injury to personnel. 

 

Part No. 

Description 

Provided w/ System 

Quantity 

D3183 

Helios 75K Drop Floodlight System, includes 

the following items: 

n/a 

D3184 

Helios-75K Light Panel w/ 100’ cable 

Yes 

D3189 

Power Console with: 

-

 

Detachable and locking 6’ power cord 

Yes 

C3206 

Helios-75K Lens Replacement Kit, includes: 

-

 

(1) Lens 

-

 

(1) O-Ring 

-

 

(1) Molykote 111 (pack) 

Yes 

 

Summary of Contents for D3183

Page 1: ...650 Phone 724 539 8060 Fax 724 805 0079 www MasterLee com MASTER LEE ENGINEERED PRODUCTS INC H HE EL LI IO OS S 7 75 5K K F FL LO OO OD DL LI IG GH HT T S SY YS ST TE EM M U US SE ER R M MA AN NU UA A...

Page 2: ...81 Latrobe PA 15650 Phone 724 539 8060 Fax 724 805 0079 www MasterLee com MASTER LEE ENGINEERED PRODUCTS INC HELIOS 75K FLOODLIGHT SYSTEM U US SE ER R M MA AN NU UA AL L Document Number EDS 18 110 Par...

Page 3: ...elios 75K Floodlight System User Manual Table of Contents 1 Safety 2 2 Electrical Requirements 4 3 Inspection 4 4 Operation Instructions 5 5 Lens O Ring Replacement 6 6 Parts List 7 7 Technical Specif...

Page 4: ...s hazards and or damage to the equipment Do not expose the Power Console to wet environments Water entering the Power Console will increase the risk of electric shock Never use the cord of the Power C...

Page 5: ...Temporary and or permanent damage to the components may occur if struck reducing performance of the light or rendering it inoperable Service Disconnect plug from Power Console before performing any a...

Page 6: ...tely transparent Discoloration of the lens may indicate embrittlement due to excessive radiation exposure Inspect all bracket and lens cover fasteners for signs of degradation damage or wear Failure t...

Page 7: ...or downwards on the cable Injury to personnel may occur IF the energized panel is touched while operating Allow a minimum of 15 minutes for the light panel to cool down prior to handling 4 2 Instruct...

Page 8: ...turning OFF the light panel 4 4 1 Depress the Power I O rocker switch to turn off the light 4 4 2 Verify the panel is not emitting light 4 4 3 Unplug the power cord from the electrical outlet 4 4 4 Al...

Page 9: ...ce and or the potential risk of hazard or injury to personnel Part No Description Provided w System Quantity D3183 Helios 75K Drop Floodlight System includes the following items n a 1 D3184 Helios 75K...

Page 10: ...Power Console 13 x 11 x 3 12 lbs Light Output Up to 78 000 Lumens Light Color Temperature 5000K white light LED Life 50 000 hours 70 lumen output Radiation tolerance Approved for extended use in React...