Spa Controls
GENERAL MESSAGES
Most messages and alerts will appear at the bottom of the normally used screens.
Several alerts and messages may be displayed in a sequence.
Some messages can be reset from the panel. Messages that can be reset will appear with a “right
arrow” at the end of the message. This message can be selected by touching the screen at the
text.
WATER TEMPERATURE IS UNKNOWN
After the pump has been running for 1 minute, the temperature will be displayed.
POSSIBLE FREEZING CONDITION
A potential freeze condition has been detected. All pumps are activated.
In some cases, pumps may turn on and off and the heater may operate during Freeze Protection.
This is an operational message, not an error indication.
THE WATER IS TOO HOT
The system has detected a spa water temp of 110°F (43.3°C) or more, and spa functions are
disabled. System will auto reset when the spa water temp is below 108°F (42.2°C). Check for
extended pump operation, high ambient temperature, or prolonged filter cycles.