DO NOT DIVE.
SWIM SPA TROUBLE SHOOTING GUIDE
SWIm Spa NOT heaTINg
* If the swim spas heater has failed, the majority of the time it will trip the GFCI breaker. If the
swim spa is not heating and has not tripped the breaker, please follow these steps:
1.
Check the control panel for diagnostic messages. Refer to your swim spa models diagnostic mes-
sage area in previous sections. Follow steps to alleviate message.
2.
Check water set temperature at control panel.
3.
Check for dirty filters. Clean if necessary.
4.
Check the “heat mode” that the swim spa is set in. The swim spa should be set in the ready
mode depending on the model.
5.
Check the control panel for heat light indicator. If the light is on and not blinking the swim spa
should be heating. Wait a reasonable amount of time (approximately 1 hour) to see if the water
temperature is rising.
6.
Check to make sure that the pump is primed and all slice valves are open.
7.
Reset power to the swim spa at GFCI breaker.
8.
If swim spa is still not heating, contact your dealer for service.
gfcI IS TRIppINg
A ground fault circuit interrupter (GFCI) is required by the National Electrical Code for your protec-
tion. The tripping of the GFCI may be caused by a component on the swim spa or by an electri-
cal problem. Electrical problems include but are not limited to, a faulty GFCI breaker, swim spa
component, power fluctuations, or improper wiring. It may be necessary to contact an electrician if
your dealer recommends doing so.