MASTER SPA - LEGEND SERIES - CONTROLS
Jets 2
Press the “Jets 2” button once to turn pump 2 on or off, and to shift between low and high speeds.
If left running, the pump will turn off after 15 minutes.
Jets 3
Press the "Jets 3" button once to turn pump 3 on or off. If left running, the pump will turn off after
15 minutes.
NOTE:
Air is injected into Master Blaster jets automatically on all equipped spas.
Jets 4 (if equipped)
Press the round auxiliary button designated for jets 4 once to turn pump 4 on and off. If left running,
the pump will turn off after 15 minutes.
NOTE:
An icon will not appear on the display when Pump 4 is activated. Please note that this is normal.
TV Lift (if equipped)
Press the “STS” button once to raise the TV;
Press the “STS” button again to lower the TV.
Invert
Press the “Warm” or “Cool” button, followed by the “Jets” button to change the numbers
in the display to read upside down.
Quick Reference LEDs
There are four LEDs on the left side of the panel that offer quick references to what spa functions are
activated. From top to bottom, these lights indicate the following: Filter Cycle 1, Filter Cycle 2, Panel
Lock, Temperature Lock.
L.E.D. Light
Press the "Light" button to turn the light on and off. If you wish to change the “function” of the lights,
turn the lights off, then on within 5 seconds. If you wish to leave the lights in the same “function”
setting for the next use, turn the lights off and do not turn back on for at least 5 seconds.
Circ Pump
Your system may be configured to work in one of three different ways:
1.
The circ pump operates continuously (24 hours) with the exception of turning off for 30 minutes
at a time when the water temperature reaches 3˚ F (1.5˚C) above the set temperature (most likely
to happen in very hot climates).
2.
The circ pump stays on continuously, regardless of water temperature.
3.
The circ pump will come on when the system is checking temperature (polling), during filter cycles,
during freeze conditions, or when another pump is on.
4.
If the circulation pump operates for more than 15 minutes without proper water flow, it will shut
down and not operate until power to the spa has been reset.
NOTE:
Factory configuration is chosen based on what the majority of users will need. If you would
like your spa to operate in a different configuration setting, your dealer can change your setting
for a fee.
39
DO NOT DIVE.