Do Not Dive.
40
REGULAR MAINTENANCE PROCEDURES
CLEANING DIVERTER VALVES - cont.
Soak the cap and handle in white vinegar.
The white plumbing fitting should also be wiped down. If the surface of the
white plumbing has become too abrasive, you can take wet, fine sandpaper
and smooth it out. It is also helpful to use a lubricant (use silicone based,
not petroleum based) to allow for an easier turn of the diverter handle.
Rinse the diverter internals and reassemble.
In the future, it is helpful to turn the diverter valve only when the pump is
not on. Cleaning your diverter valve should occur every time you drain
your swim spa.
DRAINING YOUR SWIM SPA-
Due to the physical size of the swim spa,
we recommend draining your swim spa with a submersable sump pump.
Draining your swim spa with a conventional spa drain is not a reasonable
option.
REPLACING YOUR LIGHT BULB (if equpped)
If your light bulb goes out, it is very easy to replace.
Use a 12 volt, 6 watt bulb that should be available through your dealer.
First, make sure the power to the swim spa is off.You can access the swim spa
light fitting by removing the swim spa panel.
Once the panel is removed, unfasten the black fitting inside the white
light assembly, by turning it counter clockwise.
Attached to the black fitting is the light bulb. Replace the bulb and reinsert
the fitting, by turning it clockwise.
If the white lens cap needs to be removed, insert a flat head screw driver as
shown in the picture below.
This may also be necessary when installing
an LED light.
07MS H2X Owners Manual 1/10/07 11:30 PM Page 40