DO NOT DIVE.
SWIM SPA CONTROLS - ICON SPA TOUCH
THE SETTINGS SCREEN
111
DO NOT DIVE.
HEAT MODE – READY VS. REST
In order for the swim spa to heat, a pump needs to circulate water through the heater. The pump
that performs this function is known as the “heater pump”. The heater pump can be either a
2-speed Pump (Pump 1) or a Circulation Pump.
READY MODE
If the heater pump is a 2-speed Pump 1, Ready Mode will circulate water every 1/2 hour, using
Pump 1 Low, in order to maintain a constant water temperature, heat as needed, and refresh the
temperature display. This is known as “polling”.
REST MODE
If the swim spa is not going to be used for a prolonged period of time, this mode will only allow
heating during programmed filter cycles. Since polling does not occur, the temperature display may
not show a current temperature until the heater pump has been running for a minute or two. This is
seen on the screen as:
. Using Rest Mode is not recommended in below
freezing temperatures.
NON-CIRCULATION MODE
(2-speed Pump 1)
When the heater pump has come on automatically (for example for heating or polling) you can
switch between low speed and high speed but you cannot turn the heater pump off.
CIRCULATION MODE
If the swim spa is configured for 24hr circulation, the heater pump generally runs continuously.
Since the heater pump is always running, the swim spa will maintain set temperature and heat as
needed in Ready Mode, without polling.
In Rest Mode, the swim spa will only heat to set temperature during programmed filter times, even
though the water is being filtered constantly when in 24hr circulation mode.
NOTE:
See more information on circulation modes within "Pumps" in the Swim Spa Controls - Spa
Behavior sections.
READY-IN-REST MODE
Ready in Rest Mode appears in the display if the swim spa is in Rest Mode and the Jets 1 Button
is pressed. When the heater pump has come on automatically (for example for heating) you can
switch between low speed and high speed but you cannot turn the heater pump off. After 1 hour,
the System will revert to Rest Mode. This mode can also be reset by selecting the Heat Mode.