TWILIGHT SPA – CONTROLS
TS 6.2 • TS 67.25 • TS 7.2 • TS 7.25 • TS 8.2 TS 8.25 • TS 8.3 TS 8.35 • TS 240 • TS Fit
49
L.E.D. Lights
Press the “Light” button to turn the light on and off. If you wish to change the
“function” of the lights, turn the lights off, then on within 5 seconds. If you
wish to leave the lights in the same “function” setting for the next use, turn the
lights off and do not turn back on for at least 5 seconds.
Mode
Mode is changed by pressing the “Warm” or “Cool” button, then pressing the
“Mode” button.
Standard Mode is programmed to maintain the desired temperature. Note
that the last measured spa temperature displayed is current only when the
pump has been running for at least 2 minutes. “
” will be displayed
momentarily when you switch into Standard Mode.
Economy Mode heats the spa to the set temperature only during filter cycles.
“
” will display solid when temperature is not current, and will alternate
with temperature when temperature is current.
Sleep Mode heats the spa to within 20°F/10°C of the set temperature only
during filter cycles. “
” will display solid when temperature is not current,
and will alternate with temperature when temperature is current.
Preset Filter Cycles
The first filter cycle begins 6 minutes after the spa is energized. The second
filter cycle begins 12 hours later. Filter duration is programmable for 2, 4, 6, 8
hours or for continuous filtration (indicated by “
”). The default filter time is
2 hours. To program, press “Temp” then “Jets.” Press “Temp” to adjust. Press
“Jets” to exit programming. At the beginning of each filter cycle the pump(s)
purge for 30 seconds; the pump purges for 5 minutes. The only effect filter
duration has is: 1) During the filter cycle, the low-speed of pump 1 never turns
off, and 2) In Economy and Sleep Modes, heating only occurs during the filter
cycle. On spas equipped with 24 hour circulation pumps the filter cycle is not
needed and does not operate.
Freeze Protection
If the temperature sensors detect a drop to below 44°F/6.7°C within the
heater, the pump will automatically activate to provide freeze protection.
The equipment stays on until 4 minutes after the sensors detect that the
spa temperature has risen to 45°F/7.2°C or higher.