20
DO NOT DIVE.
INSTALLATION INSTRUCTIONS
7.
It may be necessary to bleed air from the pump(s) in your spa if, after start up, your spa
pumps are turning on and off but you do not have water flow from the jets in your spa.
Due to the nature of water flow and hydro-therapy pumps, please be advised that air locking
of pumps may occur. Master Spas has taken measures to reduce the possibility of this, but it
still may occur, especially after refilling a spa. This is not a service covered under warranty.
To relieve and airlock, loosen the union on the discharge of the pump (see arrow on picture
of pump below). Water should leak out. Tighten the union and test the pump for proper jet
flow. If needed repeat process.
Airlock
Pump Union
Slice Valve
8.
Adjust water chemistry according to the instructions provided in the “Water Maintenance”
section.
9.
Your spa water will heat approximately 3 to 4 degrees Fahrenheit per hour (1 to 2 degrees
Celsius) with the cover placed on the spa. This varies depending on the size of the spa and
ambient temperatures.
10.
Step into the soothing waters of your Master Spa!
Relax and enjoy.