5.4.2 AQ Multi-circuit Heating System – Switchable Heating of DHW
Universal scheme for multi-circuit heating systems with accumulation vessel. Local regulation
can be applied here for 100% of heating output. The volume of the accumulation vessel is
determined for 15 l/kW of heating output of the heat pump for B0W35. Heating of DHW is also
provided by a 3-way switching valve. Regarding the type of DHW tank follow instructions in
Chapter “Preparation of Domestic Hot Water”.