5.4.4 AQxxIC (combi) units recommended connection
Typical usage is for floor heating, except for “dry system of floor heating”. In this method of
direct connection of the heat pump to the heating system, maximally 30% of the heating system
can be equipped by local regulation. In the case of usage for radiators it is also necessary to
comply with the requirement of minimum heating water volume of 15 l/kW of the heating output
of the heat pump at B0W35. Unit is equipped with stainless steel DHW tank volume 170l.
Important Note: Due to the stainless steel DHW tank, maximum Cl content of the tap
water could be 250ppm.
DHW outlet
tap water inlet
(! max 250ppm Cl !)
solar inlet
solar outlet
solar pump
solar system expansion
vessel and safety valve
venting valves
venting valves
Filterball
Filterball
safety valve
2.5bar
heating system
expansion
vessel
left or right outlet
internal DHW
safety valve
(P-T Relief valve 7bar, 90°C)
Ground Loop
AQxxIC machinery room