Inserting a Gas Cartridge
Remove the battery from the tool before insert-
ing the gas cartridge.
Press on the cover
2
of the gas cartridge port (
➊
)
and fold it out (
➋
).
Place the gas cartridge
19
with the attached meter-
ing valve into the port. Pay attention that the nozzle
of the metering valve engages in the small, blue
adapter
20
.
Close the cover
2
.
When inserting the gas cartridge, small
quantities of combustible gas can escape. Do
not inhale the gas, do not smoke and keep
clear from open flames or sparks.
If gas is still detectable after inserting the gas
cartridge, remove the gas cartridge immedi-
ately and check the cause.
Loading the Magazine
DIGA CS-1:
– Insert the magazine strip as shown.
– Pull the tensioning slider
12
completely to the rear
and guide it back again until it faces against the
magazine strip.
– To remove the magazine strip, pull the tensioning
slider a little toward the rear. Actuate the release
lever
13
and guide the tensioning slider
12
back.
Actuate the retaining spring
8
and pull out the
magazine strip.
DIGA WO:
– Insert the magazine strip as shown.
– Pull the tensioning slider
12
completely to the rear
and guide it back again until it faces against the
magazine strip.
– To remove the magazine strip, pull the tensioning
slider a little toward the rear. Actuate the release
lever
13
and guide the tensioning slider
12
back.
Actuate the retaining spring
8
and pull out the
magazine strip.
➊
➋
2
20
19
2
13
8
12
13
8
DIGA.book Seite 17 Donnerstag, 5. Oktober 2006 2:01 14