 Troubleshooting problems may have similar causes and solutions. 

 

PROBLEM POSSIBLE 

CAUSE 

SOLUTION 

Power cord is not plugged in. 

Plug cord into grounded outlet. 

Pressure Switch is in “OFF” 

position. 

Turn switch to “ON” or “AUTO” position. 

Wrong gauge wire or length of 

extension cord. 

Check specifications for proper gauge wire 

and cord length. 

Motor thermal overload switch is 

tripped 

Turn air compressor off, wait until motor is 

cool, then check motor circuit breaker. 

Fuse blown or circuit breaker is 

tripped. 

-Replace fuse or reset circuit breaker. 

-Check for proper fuse amperage. 

-Check for low voltage conditions. 

-Disconnect any other electrical appliances 

from circuit or operate air compressor on a 

dedicated circuit. 

Air tank pressure exceeds preset 

pressure switch limit. 

Motor will start automatically when tank 

pressure drops below cut-in pressure of 

pressure tank. 

Check valve is stuck open. 

Remove and clean or replace. 

Electrical connections are loose. 

Contact authorized service centre or store. 

Compressor 

motor will not 

run or start. 

Possible defective motor, capacitor 

or check valve. 

Contact authorized service centre or store. 

Low Voltage. 

Check power source (outlet or generator) with 

volt meter. 

Unit is plugged into an extension 

cord. 

Remove extension cord.    Tip:    It is better to 

use a longer hose instead of an extension 

cord. 

 

Shorted, or open motor winding. 

Contact authorized service centre or store. 

Motor replacement may be required. 

Motor hums 

but cannot run, 

or runs slowly. 

Check valve is defective. 

Contact  authorized service centre or store. 

Parts may require replacement. 

Incorrectly sized fuse or circuit – 

circuit overloaded.   

Check for proper fuse or breaker, use 

time-delay fuse of the proper size. 

Disconnect other electrical appliances from 

circuit or operate air compressor on its own 

branch circuit. 

Circuit is overloaded. 

Disconnect  any other electrical appliances 

from circuit or operate compressor on its own 

dedicated circuit. 

Unit is plugged into an extension 

cord. 

Remove extension cord.    Tip:    It is better to 

use a longer hose instead of an extension 

cord. 

Fuses 

blow/circuit 

breaker trips 

repeatedly. 

Check valve is defective. 

Contact  authorized service centre or store. 

Parts may require replacement. 

- 10 - 

Summary of Contents for 058-7936-6

Page 1: ...rts Missing or Damaged Questions Toll Free Help Line 1 800 689 9928 IMPORTANT Ensure that all users have read all safety rules and operating instructions carefully before using this product Keep this...

Page 2: ...UBLESHOOTING CHART 10 11 PARTS SCHEMATIC 12 PARTS LIST 12 WARRANTY 13 SPECIFICATIONSSPECIFICATION PRODUCT NUMBER 058 7936 6 PUMP 1 3 peak HP direct drive oil less PEAK HORSEPOWER 1 3 HP MOTOR 3900 RMP...

Page 3: ...s could cause serious injury 5 RISK OF BURSTING Check the maximum pressure rating in the manual or the serial number label The compressor outlet pressure must be regulated so that it does not exceed t...

Page 4: ...A ELECTRIC MOTOR AIR COMPRESSOR PUMP not visible B ON OFF SWITCH C AIR LINE OULET D REGULATED PRESSURE GAUGE E TANK PRESSURE GAUGE F AIR PRESSURE REGULATOR G PRESSURE RELIEF VALVE H AIR TANK I AIR TA...

Page 5: ...ndard Equipment 1 25 recoil hose with NPT male fitting on both ends 2 Teflon Tape 3 Blow Gun 4 Blow gun adaptor 5 Tapered inflation nozzle 6 Inflation needle 7 Ball style tire inflation chuck 8 NPT fe...

Page 6: ...4 mm NPT air hose D REGULATED PRESSURE GAUGE Display the current line pressure It is regulated by the regulator knobs E TANK PRESSURE GAUGE Indicates tank pressure in PSI F AIR PRESSURE REGULATOR A co...

Page 7: ...the use of extension cords whenever possible If an extension cord must be used it must have a minimum wire size of 12 AWG and must be no longer than 50 15 m Use only a 3 wire extension cord that has a...

Page 8: ...kwise to reach the desired pressure Do not exceed operating pressure of the tool or accessory being used 4 If a pressure regulator is present on your air compressor adjust it to the working pressure o...

Page 9: ...ure that it is operating properly and to clear the valve of any possible obstructions Daily Clean the air filter A dirty air filter will reduce air compressor performance and life To avoid any contami...

Page 10: ...essure of pressure tank Check valve is stuck open Remove and clean or replace Electrical connections are loose Contact authorized service centre or store Compressor motor will not run or start Possibl...

Page 11: ...ugged into an extension cord Remove extension cord Tip It is better to use a longer hose instead of an extension cord Thermal overload protector cuts out repeatedly Dirt covered cooling surfaces Allow...

Page 12: ...lt 4 4 Circuit Board 1 19 Cushion Pad 1 5 Washer 2 20 Fan 1 6 Bolt 2 21 Transfer Tube 1 7 Fuse 1 22 Nut M10x1 2 8 Pressure Switch 1 23 Brass Nipple 2 9 Bolt 1 24 Motor Assembly 1 10 Brass Nipple 1 25...

Page 13: ...ups or adjustments e this warranty will not apply where damage is caused by repairs made or attempted by others i e persons not authorized by the manufacturer f this warranty will not apply to any pro...

Reviews: