TROUBLESHOO
TING
22
AIR
-
POWERED COMPACT COIL ROOFING NAILER 058
-
819
1-
0
Note: For further repair information, please call 1
-
800
-
689
-
9928.
The tool does not
operate properly
-
it
does not drive the
nails or operates
sluggishly.
1. The air supply is inadequate.
2. Lubrication is inadequate.
3. The O
-
rings or seals are worn or
damaged.
4. The air deflector in the cylinder
head is blocked.
1. Verify that the air supply is adequate.
2. Add up to 6 drops of pneumatic tool oil into
the air inlet.
3. Inspect and replace O
-
rings or seals.
Have the tool serviced by a qualified service
technician.
4. Replace the damaged internal parts.
Have the tool serviced by a qualified service
technician.
The tool skips nails.
1. The bumper is worn or the spring
is damaged.
2.There is a dirt in the movable
cover.
3. Nails cannot move freely in the
magazine because of dirt or
damage.
4. The O
-
ring on the piston is worn
or dry, or there is not enough
lubrication.
5. The cylinder cover seal Is leaking.
1. Replace the bumper or the spring.
Have the tool serviced by a qualified service
technician.
2. Open and clean the movable cover.
3. Open and clean the magazine.
4. Replace the O
-
ring.
5. Open and clean the magazine.
Have the tool serviced by a qualified service
technician.
The tool jams.
1. Improper nails are used, or
nails are damaged.
2. The screw of the magazine is
loose.
3. There is dirt in magazine.
See “
Clearing the jammed nails.
”
1. Use the proper nails.
2. Tighten the nail magazine.
3. Open and clean the magazine.
Air exhaust is being
directed towards the
operator.
The direction of the air deflector
requires adjustment.
Direct the air deflector away from the operator.
PROBLEM