MAINTENANCE
23
AIR
-
POWERED CLIPPED
-
HEAD FRAMING NAILER 058
-
8434
-
4
Maintenance
DANGER!
Potential hazard that will result in serious injury or loss of life.
•
Disconnect the tool from the air compressor before performing maintenance/
service, adjusting, clearing jams, reloading, and when it is not in use.
•
Repairs must be performed by a qualif
ied service technician only. Failure to
comply will lead to serious injury or loss of life.
MAINTENANCE
REQUIRED
DESCRIPTION
TOOLS OR
MATERIALS
REQUIRED
MAXIMUM SERVICE INTERVAL
Each Use or
every 2 Hrs
Monthly
As
Needed
General inspection
-
free movement
Trigger, spring,
safety mechanism
None
X
In
-
depth inspection
Worn or broken
parts
X
X
Replace worn or
broken parts
X
Lubrication
See below
Pneumatic tool
oil
X
•
Lubrication: If the Air
-
powered Clipped
-head
Framing
Nailer and the compressor are not
equipped with an in
-
line lubrication system, place
up to 6 drops of pneumatic tool oil into the air inlet
before each work day or after every 2 hours of
continuous use, depending on the characteristics
of the workpiece and type of nails used.