DUTY-CYCLE
Range
Resolution
Accuracy
0.1
_
99.9%
0.1%
±
(1.2% rdg. + 2 dgts.)
TEMPERATURE ˚C
Range
Resolution
Accuracy
-32
_
500˚C
1˚C
±
(1% rdg. + 6 dgts.)
TEMPERATURE ˚F
Range
Resolution
Accuracy
0
_
1000˚F
1˚F
±
(1% rdg. + 8 dgts.)
CAPACITANCE (AUTO-RANGING)
Range
Resolution
Accuracy
40 nF
0.01 nF
±
(6% rdg. + 6 dgts.)
400 nF
0.1 nF
±
(2% rdg. + 5 dgts.)
4
µ
F
1 nF
40
µ
F
10 nF
100
µ
F
100 nF
The V AC and A AC ranges are specified from 5 to 100% of the range.
Input Impedance
_
10 M
Ω
(AC/DC measurement)
Diode test reads approximate forward voltage, test current of 1 mA maximum.
Continuity check audible signal will sound if the resistance is less than 30
Ω
.
Transistor test reads approximate hFE value of transistor under test.
Understanding the AC Zero Input
When measuring the AC voltage and current, the multimeter is calculating the
input and converting them to the data that the LCD can display. The converters
need certain levels of input voltage to make the measurement. This level is 5%
of the ranges for this multimeter so that the non-zero digits that are displayed on
the LCD when the test leads are open or are shorted-out are normal. They will
not affect the specified AC accuracy above 5% of the ranges.