background image

 
 
 
 
 
 

 EC 

DECLARATION 

OF 

CONFORMITY 

 

EN / DC Distribution /  July 2010

 19

 

 

10  EC DECLARATION OF CONFORMITY 

 
Manufacturer Mastervolt 

 

Address 

Snijdersbergweg 93  
1105 AN Amsterdam  
The Netherlands  

 
Herewith declares that:  
 

 

 

 

 

 

 

 

 

 

 

 

Product:  
 
77020200 

DCDistribution 500 (12/24/48V)  

 
Is in conformity with the provision of the EC EMC directive 89/336/EEC and amendments 92/31/EEC, 93/68/EEC.  
 
The following harmonised standards have been applied: 
Generic emission standard: 

EN 50081-1:1992 

Generic Immunity standard: 

EN 50082-1:1997  

 
Low voltage directive:   

2006/95/EC 

 
 
 
 
Amsterdam, 
 

 

 
 
P.F. Kenninck, 
General Manager MASTERVOLT 

Summary of Contents for 77020200

Page 1: ...O DC Distribution 500 DC Connection Device MASTERVOLT Snijdersbergweg 93 1105 AN Amsterdam The Netherlands Tel 31 20 3422100 Fax 31 20 6971006 www Mastervolt com Copyright 2010 Mastervolt v 1 3 July 2...

Page 2: ...d via the MasterBus communication platform The DC Distribution features three different menus a monitoring menu which shows the state OK or Alarm in one or more fuses a configuration menu to enter DC...

Page 3: ...tions 5 2 6 Warning regarding the use of batteries 5 3 OPERATION 6 3 1 Introduction 6 3 2 Connecting your components 6 3 3 Features 7 3 4 MasterBus displays 7 3 5 Event based programming 7 3 6 Communi...

Page 4: ...ersion includes 20 pages 1 2 GUARANTEE SPECIFICATIONS Mastervolt guarantees that this unit has been built according to the legally applicable standards and specifications Should work take place which...

Page 5: ...have access to the user s manual be familiar with the contents of this manual This applies in particular to this chapter Safety Guidelines and Measures 2 4 MAINTENANCE AND REPAIR 1 If the electrical...

Page 6: ...ed DC connections to install up to four different components Besides it provides the MasterBus network see chapter 4 with information about the fuse state To view the MasterBus information you need a...

Page 7: ...n for DC Distribution application See figure 3 Figure 3 MasterAdjust software 3 5 EVENT BASED PROGRAMMING An event is a condition to be met at which you want another device to perform a task If a fuse...

Page 8: ...ces can be added to the existing network in a very easy way by just extending the network This gives the MasterBus network a high degree of flexibility for extended system configuration not only today...

Page 9: ...not make ring networks The electric power for the network comes from the connected devices At least one device in the network should have powering capabilities see specifications One powering device...

Page 10: ...is enabled this screen reads On Disable a fuse when no component is connected This will prevent unexpected alarms On Enabled On Enabled Off Disabled Name Fuse 1 Name of fuse 1 in your DC Distribution...

Page 11: ...t data Figure 10 shows the meaning of the event data Input is a pulse followed by a longer signal 1 0 On changes the status to On at the first signal Off changes the status to Off at the first signal...

Page 12: ...d wrenches may be helpful during the installation of the DC Distribution CAREFUL Use isolated tools Materials DC Distribution Up to four fuses together maximum 500A per group See section 3 2 Five fuse...

Page 13: ...the screw on the positive strip first and fastening it with the fuse installed Fasten the parts in the right order see figure 11 a e Fasten the M8 hexagonal screws with a 9 12 Nm 80 105 InLbs torque...

Page 14: ...or MasterBus 5 Display for MasterBus data 6 Charger 7 Inverter 8 Load fuse 9 Load 10 DC wiring 11 MasterBus wiring Figure 13 shows an example of the DC Distribution in combination with the MasterShunt...

Page 15: ...100m 330ft MasterBus cable 77050200 50 pcs MasterBus connectors 77050000 Complete set to assemble MasterBus cables Delivery includes 100m 330ft UTP cable 50 pcs modular jacks and crimping tool 7704905...

Page 16: ...and terminating devices Section 4 3 MasterView display shows no DC Distribution Display not set up to show all devices Check manual of the display No voltage in one group of DC Distribution Fuse s blo...

Page 17: ...n Available languages English Nederlands Deutsch Francais Castellano Italiano Norsk Svenska Suomi Dansk Maximum fuse current 300 A Maximum current ingoing group chargers 500 A Maximum current outgoing...

Page 18: ...the centre to centre distances of the mounting holes and the DC fastening threads are displayed If you combine the DC Distribution with other MasterConnect devices especially dimension 200 mm 7 87 in...

Page 19: ...declares that Product 77020200 DCDistribution 500 12 24 48V Is in conformity with the provision of the EC EMC directive 89 336 EEC and amendments 92 31 EEC 93 68 EEC The following harmonised standard...

Page 20: ...Snijdersbergweg 93 1105 AN Amsterdam The Netherlands Tel 31 20 3422100 Fax 31 20 6971006 Email info Mastervolt com...

Reviews: