4 OPERATION
The Tanklevel Interface can monitor any volume level in your system, using any powered or non-
powered electric sensor that complies with the specifications. A typical application of this interface is
monitoring the water or fuel tank level in a ship. For this purpose, a float sensor must be mounted. To
monitor the tank level, you can use a display like the Easy View 5 for example, or a laptop or notebook
with the free downloadable MasterAdjust software. The following table shows the Tanklevel Interface
monitoring and alarms items as displayed in MasterAdjust.
Description
Default
Range
Monitoring
Level
Tank level expressed in %
-
0-100%
Volume
Tank level expressed in liters or gallons
-
Allow high alarm Option to allow an alarm for an almost full
tank
Not
checked
Not checked, checked
Allow low alarm
Option to allow an alarm for an almost
empty tank
Not
checked
Not checked, checked
Voltage
Sensor's measurement in V
0
0-63 V
Current
Sensor's measurement in mA
0
0-20 mA
Resistance
Sensor's measurement in Ohm
0
0-300 Ohm
Alarms
High level
Alarm to indicate the tank is almost full
Not
checked
Not checked, checked
Low level
Alarm to indicate the tank is almost empty
Not
checked
Not checked, checked