5.

 

M

AINTENANCE

 

Do not carry out any maintenance procedures when the machine is connected to the supply mains. 
During  this  phase  we  recommend  you  disconnect  the  cable  form  the  power  supply  mains.    For  a 
keeping a good machine efficiency, do as follows: 

 

Check the feed cables on a daily basis 

 

Keep the machine in a sheltered place 

 

Make sure that the flexible hose is not damaged in any point 

How frequently the filters are monitored will depend on the type and frequency of welding carried 
out. Regular testing of the extraction capacity of the machine is required, reduction in this capacity 
means the saturation of the cartridge filter, which will need replacing when fully saturated. 

5.1 Replacing the Cartridge Filter 

The cartride filter is part no.4  of picture 1. 
1.

 

Make sure that the machine is disconnected from the power supply mains. Then loosen the clips 
of the cover (front side - reference fig. 4) and open it. 

2.

 

Unscrew the blade-screw. 

3.

 

Take away the bar. 

4.

 

Take out the filter and insert the new one, making sure that it is well inserted. 

5.

 

Replace the bar in its original position. 

6.

 

Screw the blade-screw again. 

7.

 

Close the cover carefully by means of its clips. 

5.2 Replacing the Filter with Activated Carbons 

The filter with activated carbons is the part no. 6 in picture 1. 
1.

 

Make sure that the machine is disconnected from the power supply mains. Then loosen the clips 
fastening the cell (back side - reference fig. 4) and take it away. 

2.

 

Unscrew the four screws on the cell and replace the carbons with the new ones. Then screw the 
screws again.         

3.

 

Refasten the cell with the new activated carbons by means of the clips. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

picture 4 – Front/back sides 

 

 

Front  
side 

Back 

side 

Summary of Contents for MW 8100

Page 1: ...MW 8100 PORTABLE WELDING FUME EXTRACTOR MW 8100 USER MAINTENANCE MANUAL MW 8100 Portable Welding Fume Extractor 110V ...

Page 2: ...______________________________________________ 3 2 1 1 Highest Efficiency _______________________________________________________ 3 2 1 2 Low Noise Level ________________________________________________________ 3 2 1 3 Handiness _____________________________________________________________ 3 2 2 WORKING MODE ____________________________________________________________ 4 2 3 OVERALL DIMENSIONS ____...

Page 3: ...STICS 2 1 Technical data Weight kg 20 Motor Supply voltage Frequency V Hz 110 50 Motor Power W 1150 Capacity air flow rate m3 h 140 Total pressure mm H2O 2400 Noise Level dBA 73 Flexible Hose Length mm 60 3000 Filtering Surface m2 1 03 Activated Carbons Weight kg 2 Table 1 technical parameters 2 1 1 Highest Efficiency The high quality filtering materials of this machine make it possible to obtain ...

Page 4: ...rinth that prevents sparks from reaching the CARTRIDE filter part 4 picture 1 The air flow passes the CARTRIDE filter and then the cell with activated carbons part 6 picture 1 Inside the machine made up of a sturdy painted sheet steel there is the electric motor part 5 picture 1 picture 1 MW 8100 PARTS Pos Description 1 Nozzle with magnetized base 2 Flexible hose 60 L 3000 mm 3 Machine inlet flang...

Page 5: ...ectric power source During these operations make absolutely sure to disconnect the machine from the power supply line If the machine does not operate properly DISCONNECT IT AND LET KNOW THAT IT S OUT OF ORDER Apply to our After Sale Service for repairing it and ask for original spare parts The non observance of what has been mentioned above could endanger the equipment safety We advise the use of ...

Page 6: ...fter making sure that the ratings written in this booklet and on the machine correspond to those of the supply mains 5 Press the starting button placed on the machine side When it is in the position 1 a light inside the button will show that the machine is in its ON position picture 3 6 When suction is not needed any more press again the button position 0 The light in the button will die out pictu...

Page 7: ... were not damaged during transport otherwise contact our Reseller Place the flexible hose on the inlet flange of the machine and fasten it by means of the hose clamp Connect the power supply cable to the main electric grid after making sure that the supply voltage frequency are 110 V 50 Hz Use the machine as described in paragraph 3 1 Use direction Before connecting the machine to the main electri...

Page 8: ...e Filter The cartride filter is part no 4 of picture 1 1 Make sure that the machine is disconnected from the power supply mains Then loosen the clips of the cover front side reference fig 4 and open it 2 Unscrew the blade screw 3 Take away the bar 4 Take out the filter and insert the new one making sure that it is well inserted 5 Replace the bar in its original position 6 Screw the blade screw aga...

Page 9: ...ot purified enough Inefficacious action of filters Check their state and replace them ref to chapter 5 MAINTENANCE The machine does not develop a sufficient aspirating capacity Filters are clogged and dirty Check their state and replace them ref to chapter 5 MAINTENANCE Physical obstructions and or blockages Check whether there are any foreign bodies inside the hose Take them away The hose is brok...

Page 10: ...re 5 wiring diagram 8 DESCRIPTION OF STICKERS Picture 6 Sticker indicating that there are parts live inside the machine Picture 7 single phase motor Voltages 110 V Sticker indicating that the electric motor is single phase and that it has to be fed with 110 V MONOFASE 110 ...

Page 11: ...ag with 2 kg active carbons for portable filtration unit Model MW 8100 You are recommended to use original spare parts POS DESCRIPTION 1 Nozzle part 1 picture 1 2 Flexible hose 60 L 3000 mm part 2 picture 1 3 Filtering cartridge CARTRIDE filter part 4 picture 1 4 Refill bag with 2 kg activated carbons 5 Handle part 7 picture 1 6 Electric motor part 5 picture 1 ...

Page 12: ...ntative declares under our own responsibility that the product PORTABLE UNIT FOR FILTRATION OF FUMES MODEL MW 8100 To which this declaration is referred is in conformity to what prescribed in directives 2006 42 CE 2014 35 UE 2014 30 UE We further state that The manufacturing year is quoted on the label with EC mark placed on the machine The serial number of the machine is quoted directly on it ...

Page 13: ...MW 8100 PORTABLE WELDING FUME EXTRACTOR MW 8100 NOTES ...

Page 14: ...MW 8100 PORTABLE WELDING FUME EXTRACTOR MW 8100 NOTES ...

Page 15: ...PORTABLE WELDING FUMES FILTRATION UNIT SERIES MW 8100 NOTES ...

Page 16: ...MW 8100 PORTABLE WELDING FUME EXTRACTOR MW 8100 NOTES ...

Reviews: